Standards

EN 1627 Security Doors from a China Manufacturer

EN 1627 is the European standard for burglar resistance of doors, windows and shutters. It sorts door sets into resistance classes, RC1 N to RC6, by how long they hold against a stated attacker with stated tools. Our YK-S90-RC3 steel security door is classified to EN 1627 RC3, report ift 24-002116-PR02.

STANDARDYK DOOR · EVIDENCE INDEX
EN 1627 Security
§1EN 1627 RC3
§2EN 1628
§3EN 1629
§4EN 1630
§5five-point lock
§62.0 mm steel leaf
Tested
02 / Overview

Three tests behind one class

EN 1627 sets the classes, and three test standards decide the result. EN 1628 applies static loads to the leaf, corners and locking points. EN 1629 swings a weighted impactor at the leaf. EN 1630 has a trained tester attack the door by hand with a set tool kit for a set time. A door earns a class only when it passes all three on one build.

03 / Model

Our classification

ModelEvidenceNumberClassSize
YK-S90-RC3Classified to EN 1627ift 24-002116-PR02RC3Specimen 1000×2200 mm; single leaf to 1000×2200 mm

The tested build uses a 2.0 mm steel leaf, a five-point RC3 lock, reinforced hinges and anti-drill plates. We build to RC2 through RC6 on project specification, and the RC3 report is the class we hold.

04 / Class

The classes at a glance

ClassTypical attacker in the standardManual attack time
RC2Casual attacker with simple tools such as screwdrivers and pliers3 min
RC3Attacker with an extra screwdriver and a crowbar5 min
RC4Experienced attacker with saws, hammers and a cordless drill10 min
RC5Experienced attacker with power tools15 min
RC6Experienced attacker with high-power tools20 min
05 / Overview

Where a security door gives way

The leaf is rarely the weak point. Attacks go for the lock zone, the hinge side, the frame rebate and the frame fixing. The RC3 build closes them with a five-point lock that throws into a reinforced frame, hinge-side bolts that hold if the hinges are cut, anti-drill plates over the cylinder and frame fixings set to the tested pattern. Install the frame in the wall type the report names, or the class does not carry over. See our security door range. To place RC classes next to ballistic and storm ratings, read our guide to forced entry doors and security door rating levels.

Safe room door with multi-point bolt work
06 / Overview

Combined duties

Security doors often need a second rating. Our forced entry class sits in its own report, and fire, ballistic and acoustic ratings sit in theirs. For a door that must be RC3 and fire rated, we check the lock and reinforcement against the fire listing before production. For ballistic needs, see UL 752 bullet resistant doors.

07 / Step by step

How to specify EN 1627 doors

1

Class

Resistance class per opening, from the security assessment, for example RC3.

2

Scope

Leaf, frame, lock, hinges and glazing classified as one door set.

3

Wall

Wall type and frame fixing as tested.

4

Hardware

Cylinder class and protective fittings matched to the resistance class.

5

Other duties

Fire, smoke, ballistic or acoustic needs stated per opening.

6

Evidence

Classification report, installation instructions and a door label with the submittal.

FAQ

En 1627 security doors: questions buyers ask

RC3. Our YK-S90-RC3 is classified to EN 1627 RC3, report ift 24-002116-PR02.

09 / Item

What to send for a quote

Checklist

Tick what you already have

0/6 ready
Send what you have
Request a quote

Send your door schedule

Send the door schedule and the resistance class, and an engineer will reply with a configuration per opening. See our security door range, ballistic steel doors, all standards we work to, or our certificate register.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

Ask for a specification review

Your files stay with our engineering team and are used only to prepare your quotation.

Scroll to Top