Series · Bullet resistant doors

Bullet Resistant Door Manufacturer for Banks, Vaults and Safe Rooms

YK Door is one of the bullet resistant door manufacturers in China whose doors are UL 752 listed at Level 4 and Level 6, tested to EN 1522 class FB4 and classified RC3 under EN 1627, for banks, vaults, safe rooms and secure equipment rooms.

Bullet-resistant steel door with multi-point lock
UL 752 Level 4UL 752 Level 6EN 1522 FB4EN 1627 RC3
01UL 752 Level 4
02UL 752 Level 6
03EN 1522 FB4
04EN 1627 RC3
02 / Key points

Two routes to security

High-security doors protect against two different threats, and we treat them as two technical routes:

Ballistic protection

Stops a stated weapon and round, measured by penetration and spall on the protected side.

Forced-entry resistance

Holds out against stated tools for a stated time, measured by whether an attacker gets through.

A door can need one route or both. We confirm which at inquiry, with the standard and edition named.

03 / Route

Listed and tested performance

01

Ballistic, North America

Standard
UL 752 (11th edition)
Our result
Listed at Level 4 and Level 6
Model
YK-B4
02

Ballistic, Europe

Standard
EN 1522 / EN 1523
Our result
Tested to class FB4
Model
YK-B4
03

Forced entry, Europe

Standard
EN 1627 (tested to EN 1628, 1629, 1630)
Our result
Classified RC3
Model
YK-S90-RC3
Evidence

Certificates and test reports for bullet resistant doors

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

UL 752 listing certificate for YK Door bullet resistant steel doors
UL 752 · bullet resistant doorsets, Level 4 and Level 6
ift FB4 ballistic resistance test report for YK Door bullet resistant doors to EN 1522 and EN 1523
ift · FB4 ballistic resistance, EN 1522 and EN 1523
ift RC3 burglar resistance test report for YK Door security doors to EN 1627
ift · RC3 burglar resistance, EN 1627
04 / Step by step

A bullet resistant door is only as strong as its gaps

A test report for the steel or the glass alone does not cover the whole door. The weak points are the door gap, the keyhole, the glazing frame, the hinge edge and the joint between frame and wall. We design and verify the door as one system:

01

A continuous protective layer through leaf and frame, with overlaps at every edge.

02

Glazing clamped in frames that do not open a path around the glass.

03

Hardware kept concealed, with protected keyholes and hinge edges.

04

Frame-to-wall anchorage at the same protection level as the door.

05 / Product

Security door types

Product

Steel bullet resistant door

Configuration
Single or double swing
What we design to
Threat round, velocity, hit conditions, penetration and spall, protection level
Typical openings
Bank branches, vault corridors, guard booths
06 / Key points

Where our security doors go

Banking and finance

Branch, vault and teller doors.

Jewelry and luxury storage

Vault and forced-entry doors.

Museums and archives

Forced-entry and fire-rated storeroom doors.

Data center critical rooms

Forced-entry doors on building-level openings. See data center doors.

Private safe spaces

Faced ballistic and safe room doors.

Government and diplomatic premises

Ballistic openings at entrances, gatehouses and street facades; forced entry openings on the inner security line.

For tornado shelters, detention and anti-ligature doors, see safe room and detention doors.

Government and diplomatic premises

One door schedule carries two evidence routes. UL 752 and EN 1627 are separate reports on separate samples, so each door is marked to its own route and a ballistic leaf never fills a forced entry opening. Ratings follow the room, not the building: the gatehouse, the street facade and the records room each take the level from the threat assessment. Heavy leaves stand on their frames, so we use 2.0 to 3.0 mm frames lapped to the wall and anchored at 600 mm centers. Ballistic glass sits in steel retention frames, and lock cases are thickened with pull-resistant cylinders. In Kenya we delivered 60 ballistic and forced entry doors to government and diplomatic premises from 2021 to 2024, zone by zone. See the project card.

07 / Route

What to send for a quote

Checklist

Tick what you already have

0/3 ready
Send what you have
FAQ

Bullet resistant doors: questions buyers ask

Our YK-B4 door is UL 752 listed at Level 4 and Level 6, under the 11th edition.

09 / Product

The security range at a glance

01

Steel bullet resistant doors

Formats
Single, double swing
Evidence or design basis
UL 752 Level 4 and 6; EN 1522 FB4
02

Architectural bullet resistant doors

Formats
Swing, wood or metal facings
Evidence or design basis
Protection with concealed hardware
03

Doors with vision panels

Formats
Swing
Evidence or design basis
Protective glazing, clamping frame
04

Safe room doors

Formats
Swing, interlocked
Evidence or design basis
Continuous protection, inside release
05

Forced entry doors

Formats
Swing
Evidence or design basis
EN 1627 RC3
06

Vault doors

Formats
Heavy swing
Evidence or design basis
Drill, cutting and blast resistance, time lock

Models and evidence

ModelEvidenceNumberResultSize
YK-B4UL 752 listedUL file E518842 (BR-01)Level 4 and Level 6Single leaf to 1000×2200 mm
YK-B4Tested to EN 1522 and EN 1523ift 24-002477-PR02FB4, NS (no spalling)Single leaf to 1000×2200 mm
YK-B4-XLUL 752 listedUL file E518842 (E518842-S1)Level 4 and Level 6, vision panel includedSingle leaf to 1500×3000 mm; vision panel to 600×900 mm
YK-S90-RC3Classified to EN 1627ift 24-002116-PR02RC3Single leaf to 1000×2200 mm

Numbers are given as issued. See the full certificate register.

10 / If you need

Choosing within the range

If you need

Ballistic protection at a bank or guard room

Choose
Steel bullet resistant door
11 / Step by step

How to specify security doors

01

Ballistic

Standard, edition and full threat conditions for each door.

02

Forced entry

Attack tools, resistance time and class, such as EN 1627 RC3.

03

System

Leaf, frame, glazing, hardware and anchorage verified as one system.

04

Escape

Inside release and emergency escape stated per door.

12 / Stage

From enquiry to handover

01Threat review

Standard and threat conditions recorded

02Design

Weak points closed: gaps, keyholes, glazing frames, hinge side, frame to wall

03FAT

Construction and hardware checks

04SAT

Anchorage and locking checked

05Handover

Records by door ID

Request a quote

Send us your threat level

Send the standard, threat level and door schedule, and an engineer will reply with a configuration per opening. As a China specialty door manufacturer, we can also supply the fire, acoustic and blast doors for the same building.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

See our certifications

Your files stay with our engineering team and are used only to prepare your quotation.

Scroll to Top