Single leaf 90 minutes, double leaf 60 minutes, also CE marked and Certifire certified for export projects.
See fire-rated doorsAll products, with filters
X-ray, CT, MRI RF, airtight theater and fire doors on one submittal set, one ID per door.
See healthcare doors
How to read what a certificate, listing or test report actually proves.
Read the guide
Engineering guides on sourcing, test evidence and every specialty door type, written by YK engineers.
Browse all articlesYK Door is a China cabinet fire door factory building fire-rated, airtight cabinet and container doors for battery energy storage systems and AI server cabinets, on the same production lines that make over 100,000 fire door sets a year.

In a battery cabinet or container, the hazard is thermal runaway: ignition, gas release, rising pressure and spread from one module to the next, all linked. The door is part of that safety design, not an accessory. It has to keep its fire separation, stay sealed, open outward for escape, let rescuers in from outside, and work with the pressure relief system without becoming a projectile. In AI compute halls, dense racks bring the same questions of fire separation, airflow and access at cabinet level.
| Product | Key requirements | How we build it |
|---|---|---|
| Energy storage cabinet door | Fire separation, airtightness, external rescue access | Combined fire-rated and airtight construction, outward opening |
| Battery container door | Fire division, sealing, fast escape, weather resistance | Heavy-duty hardware, weather-resistant coating, escape-first opening |
| AI compute cabinet door | Fire separation, airflow, locking, grounding | Precision sheet metal, perforation where airflow is needed, grounding points |
| Access and equipment door | Frequent use, reliable locking, corrosion protection | Heavy-duty hinges and multi-point locks |
| Fire separation door | Fire integrity, self-closing, smoke tightness | Selected from our approved fire door configurations |
| Pressure relief interface | Vents as designed, no projectiles | Coordinated with the venting designer, opening pressure verified separately |
| Battery dry room door | Low dew point, vapor barrier, airlock | Inflatable seals with interlocked airlocks |
Our cabinet fire doors come from the factory behind our UL listed, CE marked and Certifire certified steel fire doors. They share its rock wool cores classified A1 under EN 13501-1, its ISO 3834-2 certified welding and its controlled BOMs. Each fire rating is taken from the approved configuration for that door and never carried across to a different one. See fire-rated doors.
The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.


Yes. We build fire-rated, airtight cabinet and container doors for energy storage systems, designed for outward escape, external rescue and coordination with the pressure relief system.
Yes. We supply cabinet doors to OEM drawings in batches, with CNC punching, first-article approval and change control.
Our cabinet fire doors are built from our approved fire door configurations, made on the same lines as our UL listed and CE marked steel fire doors.
We coordinate the door with the venting designer, so the relief interface vents as designed and nothing becomes a projectile. The opening pressure of the relief device is verified separately.
Yes. Our battery dry room doors use inflatable seals with interlocked airlocks for low dew point rooms.
| Product | Formats | Main duties |
|---|---|---|
| Energy storage cabinet doors | Cabinet and container doors | Fire separation, airtightness, outward escape, external rescue |
| AI compute cabinet doors | Front and rear cabinet doors | Fire separation, airflow, locking, grounding |
| Battery container doors | Personnel and equipment doors | Fire division, sealing, weather resistance |
| Access and equipment doors | Hinged, multi-point locked | Frequent use, corrosion protection |
| Fire separation doors | Self-closing | Fire integrity, smoke tightness |
| Battery dry room doors | Airlock pairs | Low dew point, vapor barrier |
| Model | Evidence | Number | Result | Size |
|---|---|---|---|---|
| YK-DC | Tested to IEC 60529 | SGS-CN-2025-IP-0731 | IP54; perforation 63 to 78% | Single door to 800×2200 mm; pair to 1600×2200 mm |
Numbers are given as issued. See the full certificate register.
Fire separation, sealing and airflow as shown for each cabinet type.
Each fire rating taken from the approved configuration for that door, never carried across.
Outward opening for escape, with access from outside for rescuers.
Interface with the pressure relief system agreed with the venting designer.
Interface dimensions, hole pattern, grounding and hardware to the OEM drawing.
First-article approval, frozen BOM and change control for every revision.
Interface, duty and responsibility split agreed
Sample built and approved against your drawing
Materials and hardware locked for the batch
CNC punching, laser cutting and standard tooling
Inspection records linked to each door ID
Packing and labeling to your takt time and assembly sequence
Send your cabinet drawings and batch plan, and an engineer will reply with a door configuration and a sample plan. As a China specialty door manufacturer, we also supply the building fire, flood and acoustic doors for energy storage and compute sites.
Your files stay with our engineering team and are used only to prepare your quotation.