Browse all articlesICC 500 is the US standard for the design and construction of storm shelters, and FEMA P-361 is FEMA's guidance for tornado and hurricane safe rooms. Both treat the door as part of the shelter's shell, so it must hold the same wind pressure and debris impact as the walls. Our YK-SH storm shelter door is tested to ICC 500 and FEMA P-361 at 250 mph, with a 15 lb 2×4 missile at 100 mph, report TTU-WISE-2025-0412.
A tornado puts two loads on a shelter door. The first is pressure: wind on the outside and suction on the leaf. The second is debris: timber, branches and roof parts thrown at high speed. ICC 500 tests both. The pressure test loads the door assembly to the design wind speed. The missile test fires a 15 lb timber 2×4 at the leaf, the hinge side and the lock side, and the door must stop it without letting it through. Our guide to security door rating levels compares ICC 500 with ballistic and forced-entry ratings.
| Model | Evidence | Number | Result | Size |
|---|---|---|---|---|
| YK-SH | Tested to ICC 500 and FEMA P-361 | TTU-WISE-2025-0412 | 250 mph wind pressure; 15 lb 2×4 missile at 100 mph | Single leaf to 1200×2400 mm |
The tests were run by an IAS accredited wind engineering laboratory in the United States. The tested build uses a 2.0 mm steel leaf with a missile impact plate, a six-point lock and heavy-duty hinges in a reinforced frame.
The rating belongs to the assembly as tested: leaf, frame, hinges, locks and anchorage to the wall. We supply all of it together and specify the anchors and wall build-up that match the test. Occupants must be able to open the door from inside after the storm, so the locks are operable from the shelter side without a key. See our storm shelter doors.

ICC 500 covers community and residential storm shelters and is referenced by the US building codes. FEMA P-361 sets FEMA's criteria for safe rooms, including those funded through FEMA grants. Our YK-SH door is tested to both, so one door model can serve either kind of project. See safe room and detention doors.
Door assemblies tested to ICC 500 and FEMA P-361 for the shelter type shown.
Tornado, hurricane or both, with the design wind speed.
Leaf, frame, hardware and anchorage supplied and installed as tested.
Locks operable from inside without a key.
Wall type and anchor pattern per the tested assembly.
Test report, drawings, anchorage details and labels with the submittal.
Yes. Our YK-SH door is tested to ICC 500 and FEMA P-361, report TTU-WISE-2025-0412.
250 mph wind pressure, and a 15 lb 2×4 timber missile at 100 mph.
Yes. The locks open from the shelter side without a key.
Yes, if the glazing is rated for the same missile. We confirm it per project.
Send the shelter drawings and hazard, and an engineer will reply with a door assembly and anchorage. See our storm shelter doors, safe room and detention doors, all standards we work to, or our certificate register.