Standards

IEC 61331 Lead Lined Doors from a China Manufacturer

IEC 61331-1 sets how the attenuation of protective materials against diagnostic X-rays is measured and stated as a lead equivalent. YK Door's X-ray shielding doors are tested to IEC 61331-1 at the National Institute of Metrology, China (report NIM-2024-RS-0271): the YK-R20 at 2.0 mmPb at 120 kV and the YK-R30 at 3.0 mmPb at 150 kV.

STANDARDYK DOOR · EVIDENCE INDEX
IEC 61331 Lead Lined
§1IEC 61331-1
§22.0 mmPb at 120 kV
§33.0 mmPb at 150 kV
§4NIM-2024-RS-0271
Tested
02 / Overview

What lead equivalence means

A door's lead equivalent is the thickness of pure lead that gives the same attenuation as the door, at a stated tube voltage. That is why the voltage always travels with the number: 2.0 mmPb at 120 kV is a different claim from 2.0 mmPb at 150 kV. IEC 61331-1 fixes how that measurement is made, so figures from different suppliers can be compared.

03 / Model

Our tested doors

ModelEvidenceNumberResultSize
YK-R20Tested to IEC 61331-1NIM-2024-RS-02712.0 mmPb at 120 kVSingle leaf to 1500×2400 mm; pair to 3000×2400 mm
YK-R30Tested to IEC 61331-1NIM-2024-RS-02713.0 mmPb at 150 kVSingle leaf to 1500×2400 mm; pair to 3000×2400 mm

Tested at the National Institute of Metrology, China, on a whole door specimen with the leaf overlap included. Lead glass vision panels go up to 800×1000 mm. See the full certificate register.

Evidence

Certificates and test reports for IEC 61331 lead lined doors

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

IEC 61331-1 lead equivalence test report for YK Door radiation shielding doors
IEC 61331-1 · lead equivalence, X-ray and CT room doorsets
04 / Overview

From shielding report to door

The shielding requirement comes from the project's physicist, who works it out from workload, use and occupancy, often following NCRP Report 147 or IAEA SSG-46. The report states the lead equivalent each wall and door needs. We match the door to that figure and keep the shielding continuous at the frame, the leaf edges, the lock and the vision panel.

05 / Point

Where shielding leaks

01

Leaf-to-frame gap

How we close it
Lead lapped into the frame rebate
02

Bottom of a sliding door

How we close it
Overlap into a floor channel or stepped threshold
03

Lock and hardware cut-outs

How we close it
Lead backing plates behind every cut-out
04

Vision panel

How we close it
Lead glass rated to the same equivalent, set in a lead-lined frame
05

Frame-to-wall joint

How we close it
Frame lead overlapped with the wall shielding

See CT room doors for rooms with heavy daily use. The floor line is covered in detail in our guide to radiation shielded door thresholds and X-ray room door shielding requirements.

06 / Overview

Hospital doors with more than one duty

Imaging doors often need to be automatic, hermetic, fire-rated or quiet as well as shielded. We build lead-lined doors with automatic sliding drives, airtight seals for clean areas and acoustic seals, and check each added duty against the shielding build. See doors for hospitals and the full radiation shielding door range.

07 / Step by step

How to specify lead lined doors

1

Lead equivalent

The figure from the shielding report, with its tube voltage.

2

Standard

Lead equivalence tested to IEC 61331-1.

3

Continuity

Shielding continuous through frame, edges, hardware and glazing.

4

Operation

Manual or automatic, swing or sliding, with safety sensors.

5

Other duties

Fire, airtightness or acoustic needs per opening.

6

Warning

Interlock with the X-ray warning light where required.

FAQ

Iec 61331 radiation shielding doors: questions buyers ask

Our YK-R20 is tested to IEC 61331-1 at 2.0 mmPb at 120 kV, and our YK-R30 at 3.0 mmPb at 150 kV.

09 / Item

What to send for a quote

Checklist

Tick what you already have

0/6 ready
Send what you have
Request a quote

Send your shielding report

Send the shielding report and door schedule, and an engineer will reply with a configuration per opening. See our X-ray shielding doors, the full radiation shielding door range, all standards we work to, or learn more about YK Door as a China specialty door manufacturer.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

Ask for a specification review

Your files stay with our engineering team and are used only to prepare your quotation.

Scroll to Top