Series · Safe room and detention doors

Storm Shelter, Safe Room and Detention Doors

YK Door builds storm shelter doors tested to ICC 500 and FEMA P-361, plus safe room, detention and anti-ligature doors, each designed and verified as a complete assembly in its installed configuration.

Safe room door with multi-point bolt work
ICC 500FEMA P-361as-installed assemblyanti-ligature hardware
01ICC 500
02FEMA P-361
03as-installed assembly
04anti-ligature hardware
02 / Door

Four doors, four goals

01

Tornado and hurricane shelter door

Main goal
Resist wind pressure and flying debris
Key interface
Whole assembly, anchorage, wall
02

Detention door

Main goal
Tamper resistance, controlled passage, observation
Key interface
Special locks, vision panel, management control
03

Anti-ligature door

Main goal
Reduce self-harm risk, keep rescue possible
Key interface
Anti-ligature hardware, rounded edges, observation, rescue access
04

Safe room door

Main goal
Protection with inside release and ventilation
Key interface
Escape logic, communication, ventilation
03 / Overview

Why each one is verified as a whole

A shelter door has to be tested and approved as a complete assembly as installed: a heavy steel plate is not a substitute. Anti-ligature performance does not come from swapping in a concealed hinge; it depends on how the whole leaf, the whole room and the care routine work together. We use the matching hardware and verification route for each type, instead of one configuration across all four.

Safe room door installed in a concrete room
04 / Key points

Standards we design to

ICC 500

Storm shelter design and components.

FEMA P-361

Safe rooms for tornadoes and hurricanes.

Detention and behavioral health

Project specifications and local operating requirements.

Models and evidence

ModelEvidenceNumberResultSize
YK-SHTested to ICC 500 and FEMA P-361TTU-WISE-2025-0412250 mph wind; 15 lb 2×4 missile at 100 mphSingle leaf to 1200×2400 mm
YK-DTTested to ASTM F1450 and F1643CABR-2025-DT-0209Grade 3; 15 min attack resistanceSingle leaf to 1200×2400 mm

Numbers are given as issued. See the full certificate register.

05 / Sector

Where these doors go

Sector

Schools and public shelters

Typical package
Storm shelter doors
FAQ

Safe room and detention doors: questions buyers ask

Yes. Our storm shelter doors are tested to ICC 500 and FEMA P-361 as complete assemblies, including anchorage to the wall.

07 / If the room is

Choosing within the range

01

A tornado or hurricane shelter

Start with
Storm shelter door, tested to ICC 500 and FEMA P-361
02

A holding cell or detention area

Start with
Detention door
03

A psychiatric bedroom or bathroom

Start with
Anti-ligature door with rescue access
04

A refuge room

Start with
Safe room door with inside release and ventilation
08 / Step by step

How to specify these doors

01

Standard

ICC 500 and FEMA P-361 for shelters; the project specification and local operating requirements for detention and anti-ligature doors.

02

Assembly

Leaf, frame, hardware and anchorage supplied as one configuration, as installed.

03

Risk scenario

Wind and debris, attack or self-harm stated for each opening.

04

Release and rescue

Inside release for shelters and safe rooms; outside rescue access for anti-ligature doors.

05

Hardware

Designed as one set for the door's duty.

09 / Item

What we confirm before design

ItemWhy it matters
Applicable standard and editionSets the design basis
Full assembly configurationThe door is verified as installed
Wall type and anchorageCarries the load into the building
Risk scenarioDecides hardware, edges and glazing
Management requirementsLocks, staff control and observation
Evidence

Certificates and test reports for storm shelter, safe room and detention doors

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

ICC 500 storm shelter door test report for YK Door storm shelter doors
ICC 500 · storm shelter doorsets, FEMA P-361
ASTM F1450 detention door test report for YK Door detention doors
ASTM F1450 · detention doorsets
10 / Step

From specification to handover

01

Specification

What happens
Standard, risk scenario and door schedule confirmed
02

Design

What happens
Assembly, hardware set and anchorage drawn
03

Production

What happens
Built to the designed configuration, one ID per door
04

Installation

What happens
Frame anchored to the detail, hardware fitted as a set
05

Acceptance

What happens
Release, rescue access and latching tested
06

Upkeep

What happens
Maintenance checklist for hardware and anchors
Request a quote

Send us your project spec

Send the standard, risk scenario and door schedule, and an engineer will reply with a configuration. As a China specialty door manufacturer, we cover the rest of the building's doors too.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.