By Chunjie Zheng, Technical Director, YK Door Industry · 17 years in fire door engineering · Technically reviewed by Yulin Zhang, General Manager
The short answer: Security door rating levels answer specific threats, and each rating system measures something different. EN 1627 resistance classes measure how long a door resists a burglar with defined tools. UL 752 and EN 1522 measure resistance to specific firearms and ammunition. ICC 500, used with FEMA P-361, measures whether a shelter door survives tornado wind pressure and flying debris. Pick the system that matches your threat first, then the level within it.
The most expensive mistakes with security doors happen before anyone talks to a manufacturer. A specification asks for “bullet-proof doors” without naming a threat, so the project gets either an under-rated door or a very heavy one with hardware, frames and walls struggling to keep up. Another asks for a high forced-entry class for a room whose real risk is a tornado. This guide works through a threat-to-rating map, from tools to firearms to tornado debris, explains what each rating system measures and where it stops, and closes with a facility-by-facility map.
Forced-entry door ratings at a glance
For burglary and intrusion, the European reference is EN 1627, which grades complete doorsets from RC1 to RC6 by the tools an attacker carries and the minutes the door must hold. Pick the class from the attacker profile and the response time, then ask for the classification report for the complete doorset, not only the lock.
| EN 1627 class | Attacker and tools assumed | Resistance time in the manual test | Typical openings |
|---|---|---|---|
| RC2 | Opportunist with simple tools such as screwdrivers, pliers and wedges | 3 minutes | Apartment entrances, offices |
| RC3 | Adds a second screwdriver and a crowbar | 5 minutes | Commercial entrances, plant rooms, server rooms |
| RC4 | Experienced attacker with saws, hammers, axes and a cordless drill | 10 minutes | Retail back-of-house, pharmacy and cash rooms |
| RC5 | Adds power tools such as a drill, jigsaw and angle grinder | 15 minutes | High-value stores, data center secure rooms |
| RC6 | Adds high-powered power tools | 20 minutes | High-security facilities |
Forced-entry and ballistic ratings answer different threats, so a door that needs both carries two separate pieces of evidence, explained below. The class requirements are summarized on our EN 1627 security doors page.
Start with the threat, not the door
A security rating is only meaningful against a threat definition, so the first document in a security door project should be a threat assessment, not a product brochure. It answers three questions. Who or what is the door protecting against: an opportunist, a determined intruder with tools, an attacker with a firearm, or a storm? How long does the door need to hold: long enough for a response team to arrive, for occupants to reach a safe room, or for the duration of a tornado’s passage? And what else must the door do every day: allow egress, carry glazing, meet a fire rating, stay accessible?
The answers sort the opening into one or more of three families of rating. Forced-entry ratings deal with time against tools. Ballistic ratings deal with a defined weapon and ammunition at a defined distance. Shelter ratings deal with wind pressure and windborne debris. Many openings need two families at once, such as a bank teller line that needs ballistic and forced-entry resistance, or a school safe room that must resist tornado debris and still meet fire and egress codes. When that happens, each performance needs its own evidence. That is the theme of our guide on combined performance door ratings.
Security door rating levels on one ladder
Each rung below answers a different threat, and a door may need to stand on more than one. Read across, not just up.
| Threat | Rating system | What the rating measures | Typical question |
|---|---|---|---|
| Opportunist burglar | EN 1627 RC2 to RC3 | Time against defined tools | How long until response arrives? |
| Determined attacker with power tools | EN 1627 RC4 to RC6 | Time against heavier tools | What is behind the door? |
| Handgun | UL 752 lower levels, EN 1522 FB1 to FB4 | Stops defined rounds | Which weapon is credible? |
| Rifle | UL 752 rifle levels, EN 1522 FB5 to FB7 | Stops defined rounds | Is spall protection needed? |
| Tornado debris | ICC 500, FEMA P-361 | Pressure and missile impact | Is it a code-required shelter? |
| Combined entry and ballistic | Project requirement, FE/BR | Defined attack sequence | Which agency’s criteria apply? |
Forced entry: buying time against tools
Forced-entry ratings assume that a determined person will eventually get through any door. What the rating buys is time, enough for an alarm to trigger a response or for people inside to reach safety. In Europe, EN 1627 sets out six resistance classes, RC1 to RC6, each tied to a burglar profile, a tool set and a timed attack. At the lower end, entry classes resist simple levering tools for a few minutes; Griffwerk notes, for example, that the lever test for RC3 runs five minutes [3]; that is a test resistance time under defined tools and methods, not a guaranteed delay in a real break-in. The higher classes, RC4 to RC6, bring in saws, axes, cordless drills and powerful power tools, and they are mainly used in commercial and high-security buildings [3].
A forced-entry class is a property of the complete door set: leaf, frame, hinges, locks, glazing and the fixing into the wall, tested together. That is why a high-security lock fitted to an ordinary door does not create a rated door, and why the wall around a rated door matters as much as the door. YK-S90-RC3 is classified to EN 1627 RC3 today, with RC2–RC6 by project test.
Ballistic: UL 752 in the United States
For firearms, US projects usually specify UL 752. It defines levels by weapon, ammunition and number of shots, and it is easy to misread because the levels are not a simple ladder. For the Edition 11 framework discussed here, Level 4 and Level 6 represent different threats rather than a simple ranking: Level 4 uses one .30-caliber rifle round, and Level 6 uses five high-velocity 9 mm rounds. As one manufacturer’s summary puts it, the levels “do not progress in a linear pattern” [1]. Match the specified threat and standard edition to the supporting evidence, rather than selecting by level number alone.
That non-linear structure has a practical consequence for specifiers: a higher number is not automatically a better door for your threat. A Level 6 door is tested against repeated high-velocity 9 mm rounds, a Level 4 door against a single rifle round; which one fits depends on the weapons in the threat assessment. Some projects need both, which is why doors are often tested at more than one level. YK-B4 is UL 752 listed at Level 4 and Level 6 (Edition 11).
The edition matters too. Edition 11 uses numbered performance levels, while Edition 12 uses a different designation system [6]. This article states YK-B4 under Edition 11, so the project specification and evidence review should use the matching edition and threat definition.
Ballistic: EN 1522 in Europe and how to compare
European and many international projects use EN 1522 for doors, windows and shutters, with seven FB classes defined by weapon, caliber and test distance; FB4, for example, covers .357 Magnum and .44 Remington Magnum handgun threats [2].
Comparing EN 1522 with UL 752 is a common request on international projects, and there is no exact conversion. The weapons, distances, shot patterns and pass criteria differ, so the honest answer is to compare threat descriptions rather than level numbers. If a US project asks for a door “equivalent to FB4”, the safer route is to state the actual threat and ask which evidence covers it. YK-B4 has an EN 1522 FB4 classification and UL 752 Level 4 and Level 6 evidence under Edition 11. For each project, match the supplied configuration to the evidence for the standard named in the specification.
From the factory floor
Two things keep the vision panel and frame at the same level as the leaf: testing the whole assembly and clamping the edges. The laminated ballistic glass is held by a steel clamping frame with at least 25 mm of edge cover, so the first row of fixings cannot be shot through, and the frame overlap is at least as thick as the plate, so there is no straight path for a round. Edges and joints have to be inside the tested configuration, not just the middle of the panel.Yulin Zhang, General Manager
Tornado and storm shelters: debris and pressure
Tornado shelter doors face a threat that is neither human nor ballistic: extreme wind pressure combined with debris flying at highway speeds. In the United States, shelters are designed to ICC 500, and FEMA P-361 sets out the federal criteria for community and residential safe rooms. For the 250 mph residential tornado safe-room design described in FEMA guidance, vertical surfaces are evaluated for impact from a 15-pound 2×4 at 100 mph [4]. The project should identify the applicable shelter type, design wind speed and ICC 500 edition before selecting the door assembly.
FEMA’s own guidance on safe room doors is blunt about why this matters. Its November 2024 fact sheet warns that ordinary steel doors “cannot withstand the impact” of tornado-borne debris, and that a storm door with three locks and three hinges is not a substitute for a tested assembly [5]. Manufacturers must certify that their door assemblies passed ICC 500 testing, compliance is shown by a label applied under a third-party certification agency, and new products in FEMA-funded safe rooms where ICC 500-2023 is adopted should reference that edition [5]. FEMA itself does not certify products, so the label and the certifier’s listing are the references to check [5].
The fact sheet also makes the assembly point clearly: the door, locks, hinges, frame and the anchors into the specific wall type must all match what passed the test, and substituting hardware can cause the door to fail [5]. For buyers, the questions are therefore whether the door assembly carries a permanent ICC 500 label, whether the supplied hardware is identical to the certifier’s listing, whether the installation instructions match your wall type, and how the door meets egress and accessibility requirements once the storm has passed. Our storm shelter doors page describes the door types we build for shelters.
The whole opening has to match
Every rating in this guide applies to a tested opening, and the weakest component decides real-world performance. For ballistic doors, the frame needs the same protection as the leaf, the glazing needs its own rating at the same level, and the gaps at the edges need to be overlapped or protected so a round cannot find a straight path. For forced-entry doors, the hinge side is often the target, so hinge bolts or dog bolts, reinforced frames and anchorage into a wall of matching strength all matter. For shelter doors, latching and anchorage carry the load.
Weight is the practical constraint that ties all of this together. Ballistic and high-security doors are heavy, and that weight drives hinge selection, closer sizing, frame gauge, anchorage and even how the door is shipped and installed. Planning for it early avoids the late substitution of lighter hardware that quietly undermines the rating.
From the factory floor
Bank and safe room clients care about three things: the exact ammunition and number of shots behind the rating, egress from the protected side, and whether the door can look like an ordinary door. The first is the one that gets blurred. UL 752 Level 4 is one .30-caliber rifle round and Level 6 is five high-velocity 9 mm rounds, so they are not a ladder where a bigger number is better. We write the ammunition and shot count on the door schedule to avoid disputes later. A 1000 x 2100 mm leaf weighs 110 to 150 kg, so we specify three bearing hinges, size the closer to the weight and add backing plates to the frame. Two people cannot lift it, so it needs a hoist or a leaf trolley, and the floor must be level or the weight will pull the frame out of line. We calculate lifting points and center of gravity before shipping and send installation drawings with the doors.Yulin Zhang, General Manager
Writing a threat statement a supplier can use
A good statement is short, and it replaces a vague word such as “secure” with facts. It should cover four things.
The adversary
Name who the door has to stop: a casual intruder, a prepared burglar, or someone with a firearm. The consultant may also state the skill level and tools expected.
The weapon or tool
For ballistic threats, state the weapon and ammunition, or the rating that defines them. For forced entry, state the class or the tool set.
The time needed
State how long the door must hold, based on how quickly help will arrive. This is often the most useful number in the brief, and it is frequently missing.
The protected side
State which side faces the threat, and what is behind the door. People directly behind a door may raise the question of spall, while equipment rooms may not.
Example statement: “Cash room door, threat from corridor side. Handgun threat to UL 752 Level 3 by Edition 11. Forced entry resistance equal to EN 1627 RC3. Response time 10 minutes. Staff directly behind the door, no spall permitted.”
Treat the example as a format rather than a recommendation, because the levels should always come from your own assessment.
Matching threats to ratings by facility type
The table is a starting point for a conversation with your security consultant. Every project’s threat assessment can move these choices up or down.
| Facility or opening | Typical primary threat | Rating family to start from | Points to check |
|---|---|---|---|
| Bank teller line, cash room | Handgun attack, forced entry | UL 752 or EN 1522, plus forced entry | Glazing level, transaction openings, frame protection |
| Embassy or government entrance | Firearms, forced entry, blast | UL 752 and forced-entry, often combined with blast | Combined evidence, US federal FE/BR where required |
| Data center or vault perimeter | Forced entry with tools | EN 1627 RC class or equivalent | Hinge side protection, wall construction |
| School or community safe room | Tornado debris and pressure | ICC 500 / FEMA P-361 | Egress, accessibility, latching under load |
| Residential safe room | Tornado, intruder | ICC 500, plus forced entry where needed | Door size, hardware, installation in the house frame |
| Behavioral health or detention | Self-harm, assault, forced entry | Facility-specific detention and anti-ligature criteria | Hardware, glazing, operating forces |
Once you know which family applies, our engineers can quote against the standard and edition you name.
For federal facilities in the United States, forced-entry and ballistic requirements are often written as FE/BR ratings with their own test protocols. For detention and behavioral health settings, the threat is different again, and the design priorities change accordingly.
Evidence and comparison
Reviewers and buyers often need to compare systems and see proof. This is how to do that without inventing equivalences.
Forced-entry evidence: the EN 1627 classification report
Forced-entry resistance in Europe is classified under EN 1627 after testing to the related methods, and the classification report names the tested door, its size, hardware and glazing. Our YK-S90-RC3 is classified to EN 1627 RC3, with RC2 to RC6 available by project test. Check the report against your opening for size, leaf type, lock and cylinder, glazing and the wall it was fixed into.
Ballistic evidence: the UL 752 listing and the EN 1522 classification
Bullet resistance in the United States is listed under UL 752, and the listing names the level, the edition and the construction. Our YK-B4 is listed to UL 752 Level 4 and Level 6 under Edition 11, and its listing includes vision panels up to 600 × 900 mm. In Europe, bullet resistance is classified under EN 1522; YK-B4 holds FB4 NS, tested on an unglazed specimen, so glazed versions rely on the UL 752 listing or further testing. A ballistic document says nothing about tool attack, and a forced-entry report says nothing about firearms.
Storm shelter evidence: ICC 500 and FEMA P-361
Storm shelter doors are tested to ICC 500 and FEMA P-361: YK-SH is tested to both, at 250 mph design wind and with a 15 lb 2×4 missile at 100 mph. Each document covers what it says and no more.
Comparing ratings across standards
Buyers often ask how a European rating compares with a US one, or how forced-entry ratings compare with ballistic ratings. The honest answer is that they measure different things with different methods, so they do not convert neatly. An EN 1627 class describes resistance to a set of tools for set times; a UL 752 level describes resistance to specified rounds; an EN 1522 class does the same with European ammunition and methods. A door may hold ratings in several systems, but each must be shown by its own test. Choose the system the project’s market and threat assessment require, and ask for evidence in that system.
A worked example: a bank branch
Say a bank refurbishes a branch with a cash-handling room and a staff entrance. The security consultant’s threat assessment calls for ballistic resistance against named ammunition and shot counts at the counter screen and the cash-room door, forced-entry resistance against tools at the staff entrance and both on the cash-room door. The supplier offers a door listed to UL 752 Level 4 for the cash room, with a vision panel within the listed size, and a door classified to EN 1627 RC3 for the staff entrance, matching the project’s market. The reviewer checks that each door’s hardware, frame and wall match the evidence, and that the cash-room door’s forced-entry resistance is supported by evidence on the same construction. The wall around each door is built to the same level, so that the door is not the only protected element. The consultant signs off the package before production.
Applying the ratings to a real opening
Ratings describe tests, and projects have openings. These sections show how a rating turns into a door you can install and use.
The wall and frame must match
A rated door needs a wall that holds the same line. Attackers and projectiles take the easiest path, so walls, frames, glazing and any adjacent openings must provide resistance comparable to the door. Frames must be anchored into structure that can carry the loads in the test, and gaps between frame and wall must be filled so that they do not become weak points. Specify the wall construction alongside the door, and ask the supplier for the anchorage and filling details that match its evidence.
Hardware and glazing choices
Hardware is part of the rating. Locks, hinges, closers and any electrified hardware must be those tested or listed with the door, or covered by the evidence. Glazing is often the limit: larger panels need thicker, heavier glass, and the listing or classification sets the maximum size. Substituting hardware or enlarging glass without checking the evidence can quietly reduce the door’s resistance. Ask for the hardware schedule and glazing sizes in the submittal, and check them against the listing or classification report.
Accessibility and egress
Security doors on accessible routes must still meet opening force and clear width requirements, and doors on escape routes must open from inside without special knowledge. Heavy ballistic and forced-entry doors often need power assistance to meet opening force limits, and electric locking must release as the escape strategy requires. Check these requirements with the access and fire consultants during design, and make sure the hardware chosen is covered by the security evidence. A door that meets its security rating but fails accessibility or egress will be rejected, and changing hardware afterwards can affect the rating. Bring the security, access and fire consultants together for one review of every security door before production.
Storm shelter doors in practice
Storm shelter doors protect people from extreme wind and wind-borne debris, so their evidence comes from tests to ICC 500 and FEMA P-361 rather than from forced-entry or ballistic standards. The door, frame, hardware and anchorage must be the tested assembly, installed into a shelter structure designed to the same standard. Shelter doors must open outward or inward as the shelter design requires, and they must be operable from inside after the event, so latches and hinges are designed to remain functional. Schools, community shelters and safe rooms in homes and businesses all use these doors, and local codes may require them in certain buildings. YK-SH is tested to ICC 500 and FEMA P-361, at 250 mph design wind and with a 15 lb 2×4 missile at 100 mph.
Testing in the field
Security doors are not usually tested again on site, so their protection depends on installation matching the tested assembly. Inspect frames, anchorage, gaps, hardware and glazing against the installation instructions before handover, and photograph each door. The photographs and inspection record support the record that each door was fitted as tested, alongside inspections made before concealed work is covered, and they give maintenance teams a reference for later repairs.
Buying and looking after security doors
Ordering, lead times and records decide how smoothly a rated door reaches the project and stays in service.
Ordering security doors
Give the supplier the threat assessment’s requirement for each opening: the standard, the level or class, the market, the wall construction, the hardware functions, glazing sizes and any other duties such as fire or accessibility. Ask for the listing or classification report for each door type and check that it covers the size, hardware and glazing ordered. Agree installation details, especially anchorage and frame filling, and whether the supplier will supervise installation. Security doors are expensive to correct after installation, so the time spent matching evidence to openings before ordering is well spent.
Planning lead times
Security doors with listings or classifications are made to tested constructions, but sizes, hardware and finishes vary by project, so allow time for drawings, approval, production and shipping. Materials and ballistic glazing need their own lead times in the schedule. Order early, especially where the security consultant must approve drawings before production, and plan installation with the wall construction so that anchorage is ready when the doors arrive. A late security door often delays the handover of the whole protected area, because the space cannot be used until its perimeter is complete.
Maintenance and inspection
Security doors are tested as new, and their protection depends on staying that way. Inspect hinges, locks, frames and glazing regularly, check that doors close and latch fully and replace damaged parts only with approved items. Record inspections and repairs, because insurers and security auditors may ask for them.
Records for owners and insurers
Keep the threat assessment, door evidence, installation records and inspection history together. Insurers and security auditors may ask for them, and they guide repairs and replacements years later.
A final check
Before ordering, walk the schedule once more with the threat assessment beside it. Every opening should have a standard, a level, a market, a wall type and a document that covers its size, hardware and glazing. Any opening without all five is not ready to order, however good the price.
Security door mistakes that cost the most
Rating the leaf only
The leaf gets all the attention, yet a frame, glass panel or lock can decide the result. Ask what the test covered, and confirm that those parts are on your door.
Treating numbers as a ladder
A higher level number does not always mean a stronger door for your threat, especially across standards and editions. Compare the threat descriptions.
Forgetting daily use
A rated door that staff prop open offers no protection. Check weight, closers, access control and traffic before finalizing the design.
Ignoring the wall
A strong door in a weak wall simply moves the attack to the wall. Bring the wall’s rating into the same review.
Reading a security door data sheet
Forced entry door rating claims
What the sheet should state
Look for the standard, the class and the complete doorset that was tested, including hardware and frame.
What to ask next
Ask how the wall should be built and fixed, because the class assumes a suitable surrounding structure.
Bullet resistant door levels on a data sheet
What the sheet should state
Look for the standard, level or class, edition, and whether glazing and frames were part of the test.
What to ask next
Ask which side faces the threat, and how spall is handled on the protected side.
Frequently asked questions
What are forced entry doors?
Forced entry doors are complete doorsets tested to resist an attacker with hand and power tools for a stated working time. In Europe they are classified under EN 1627 from RC1 to RC6. RC3, for example, resists an experienced burglar with screwdrivers and a crowbar for at least 5 minutes. The class covers the leaf, frame, lock, hinges and the fixing to the wall together.
What is the difference between forced-entry and ballistic door ratings?
A forced-entry rating such as EN 1627 measures how long a door resists a burglar with defined tools. A ballistic rating such as UL 752 or EN 1522 measures resistance to a defined weapon and ammunition at a defined distance. Many openings need both, each with its own evidence.
Is UL 752 Level 6 higher than Level 4?
The levels describe different threats. Under Edition 11, Level 4 uses one .30-caliber rifle round and Level 6 uses five high-velocity 9 mm rounds. Choose by the weapons in the threat assessment and the edition named in the specification.
Is EN 1522 FB4 equivalent to a UL 752 level?
There is no exact conversion, because weapons, distances, shot patterns and pass criteria differ. Compare the threat descriptions and ask which evidence covers the stated threat. YK-B4 holds an EN 1522 FB4 classification and UL 752 Level 4 and Level 6 evidence under Edition 11.
What does EN 1627 RC3 mean?
RC3 is one of six resistance classes, RC1 to RC6, each tied to a burglar profile, a tool set and a timed attack. The class belongs to the complete door set: leaf, frame, hinges, locks, glazing and the fixing into the wall, tested together.
What rating does a tornado shelter door need?
In the United States, shelter doors are tested to ICC 500 and used within FEMA P-361 criteria. For a 250 mph residential safe room, vertical surfaces are evaluated for a 15-pound 2×4 at 100 mph. Compliance is shown by a label applied under a third-party certification agency.
Does a security door need a matching frame and wall?
Yes. The rating covers the tested opening, so the frame, glazing, edge overlaps, hinge-side protection and anchorage into a wall of matching strength all carry the same level. The door weight also sets hinges, closer, frame gauge and anchorage, so plan them together.
Does YK-B4 hold both UL 752 and EN 1522 ratings?
YK-B4 is listed to UL 752 Level 4 and Level 6 under Edition 11, including vision panels up to 600 × 900 mm, and classified FB4 NS under EN 1522 on an unglazed specimen. Glazed versions rely on the UL 752 listing or further testing.
How are storm shelter doors evidenced?
By testing to ICC 500 and FEMA P-361. YK-SH is tested to both, at 250 mph design wind with a 15 lb 2×4 missile at 100 mph.
Before you request a quote
A security door quotation is only as good as the threat description behind it. Before you request one, write down the threat for each opening (tools and time, weapon and ammunition, or wind and debris), the standard and edition you want to use, any second performance such as fire or blast, the glazing and hardware you need, and the wall construction around the door. With that information, suppliers can quote the same thing, and your reviewer can check the evidence against the threat rather than against a level number.
Turn your threat assessment into a clear door requirement. Send the required standard and edition, opening sizes, glazing, hardware and wall construction to request a security door quotation from YK Door. The builds are shown on our ballistic steel doors and safe room and detention doors pages.
Sources
- Delta Scientific, The 10 UL 752 Levels of Bullet Resistant Glass, 25 November 2024. https://deltascientific.com/2024/11/25/levels-of-bullet-resistant-glass/
- SITEC GmbH, What are ballistic classes? (EN 1522 summary). https://www.sitec.de/?p=8069
- Griffwerk, Burglary protection: burglar-resistant windows and doors. https://griffwerk.de/en/blog/burglary-protection