Imaging rooms depend on doors that keep radiation and radio-frequency energy where they belong while staying easy to use every day. These guides explain how a physicist's shielding design becomes a door specification for X-ray, CT, PET and radiotherapy rooms, and how MRI doors achieve and keep their RF attenuation. Topics include lead equivalence, lead glass, interlocks, fingerstock seals, field testing and maintenance. They are written for hospital planners, imaging equipment vendors, shield room integrators and contractors building or renovating a radiology suite.
Each cornerstone guide covers the whole topic end to end. The articles in its series go deeper into one question each.
Cornerstone guide
Publishing soonThe questions below map the article series behind each cornerstone guide. Linked titles are live; the rest are being written by our engineers.
It needs a floor detail that carries the shielding under the leaf: a lead-lined threshold plate, lead sheet in the floor build-up extending past the door line on both sides, or, on sliding doors, a bottom overlap onto a lined floor guide. The gap under the leaf is kept as small as operation allows, and the floor line is part of the physicist’s survey. Read more in X-Ray and CT Room Doors
The amount comes from the medical physicist’s shielding report for that room, based on design goal, workload, occupancy, distance and radiation quality. For many radiographic rooms, 1/16 in. Read more in X-Ray and CT Room Doors
It is the thickness of pure lead that gives the same attenuation as the door’s construction at a stated tube voltage. Lead equivalence is quoted with its kV, for example 2.0 mmPb at 120 kV for YK-R20 and 3.0 mmPb at 150 kV for YK-R30, both tested to IEC 61331-1. Read more in X-Ray and CT Room Doors
Upload your door schedule or specification and an engineer maps each clause to a configuration and the document behind it. Learn more about YK Door, a China specialty door manufacturer.