Data hall corridor with a pair of steel security doors
Industries · Data centers

Data Center Door Supplier for Racks, Aisles and Buildings

YK Door is a data center door supplier for colocation, hyperscale and AI compute facilities. We split the data center into four layers (rack, aisle, building and equipment), each with its own products, quotation and service, so rack makers, integrators and contractors each get what they buy.

014 layers
02UL listed fire doors
03STC 48 acoustic
04ASTM E331 flood tested
02 / Overview

Three supply chains, one building

Data center doors come through three procurement systems that rarely meet: rack manufacturing, building construction and cooling equipment. A single product logic does not fit all three. We set up each layer separately and keep them on one numbering rule, so the owner gets one record for every door in the facility.

03 / Layer

Four layers

01

Rack

Products
Perforated front and rear doors, electronic-lock doors. See AI server cabinet doors.
What matters
Hole position accuracy, open area, grounding, coating, batch consistency
Main buyers
Rack makers, server OEMs
02

Aisle

Products
Hot and cold aisle doors, cage doors, aisle end doors
What matters
Airflow separation, fast installation, access control
Main buyers
Integrators, operators
03

Building

Products
Data hall fire-acoustic doors, plant room fire doors, flood doors, security doors
What matters
Combined fire, acoustic, flood and security performance
Main buyers
Main contractors, door contractors, owners
04

Equipment

Products
Rear door heat exchangers, with thermal partners
What matters
Heat load, water circuit, pressure drop, condensation
Main buyers
Cooling vendors, integrators
04 / Duty

Building-level evidence

01

Fire

Evidence
UL listed to UL 10B and 10C; CE marked to EN 16034; Certifire
02

Acoustic

Evidence
STC 48 and Rw 47 dB
03

Flood

Evidence
FM Approved to ANSI/FM 2510, up to 1.2 m water head
04

Security

Evidence
UL 752 Level 4 and 6; EN 1627 RC3
05 / Opening

Products for the data center

01

Data hall entrance

Product
Fire-acoustic steel doors. See steel fire doors.
02

Generator and chiller rooms

Product
Acoustic steel doors
03

Ground floor and basement plant

Product
Flood doors
04

Critical and meet-me rooms

Product
Ballistic and security doors
05

Battery and UPS rooms

Product
Energy storage cabinet doors, fire separation doors
06

Modular data halls

Product
Container and modular fire doors
07

Loading docks

Product
High speed doors
06 / Key points

How each layer is delivered

Rack

First-article approval and production on fixed tooling, so every batch matches.

Building

Doors submitted against the project's fire and acoustic specifications.

Equipment

Thermal figures, water quality, pressure drop and maintenance responsibility defined in writing.

07 / Overview

AI compute changes the numbers

AI racks draw more power and move more air per cabinet. That raises the stakes on rack door open area, puts liquid cooling at the rear door, and brings fire separation down to cabinet level next to dense battery and UPS rooms. We supply each piece from the same factory. See data center doors and cabinet fire doors.

Fire-rated steel door next to server racks in a data hall
FAQ

Data centers: questions buyers ask

Yes. We supply rack, aisle, building and equipment-level doors, each set up for its own buyer and delivered on one numbering rule.

09 / Layer

Standards by layer

01

Rack

What governs the design
Customer drawings, IEC and ANSI rack accessory requirements, vendor specifications
02

Aisle

What governs the design
Integrator's module interfaces and access control system
03

Building

What governs the design
Fire, acoustic and watertight standards for each opening, such as UL 10B and 10C and ASTM E90
04

Equipment

What governs the design
Thermal and fluid requirements set with specialist partners
05

Grounding and EMC

What governs the design
Project requirements
Evidence

Certificates and test reports for data center projects

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

Flood abatement door to ANSI/FM 2510 for YK Door flood and watertight doors
FM 2510 · flood abatement, 0.9 m and 1.2 m water head, 30 min
ift FB4 ballistic resistance test report for YK Door bullet resistant doors to EN 1522 and EN 1523
ift · FB4 ballistic resistance, EN 1522 and EN 1523
ift RC3 burglar resistance test report for YK Door security doors to EN 1627
ift · RC3 burglar resistance, EN 1627
IEC 60529 IP54 ingress protection test report for YK Door cabinet fire doors
IEC 60529 · IP54 ingress protection, cabinet doorsets
10 / Layer

Who sets the spec, who buys

Sets the specification
OEM engineering, purchasing and quality
Places the order
Rack and server makers

11 / Layer

What to send for each layer

Checklist

Tick what you already have

0/4 ready
Send what you have
Request a quote

Send your data center schedule

Send the door schedule, rack drawings or both, and an engineer will reply with a configuration for each layer. Read about YK Door as a China specialty door manufacturer and see doors for every sector.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

OEM and ODM partnership

Your files stay with our engineering team and are used only to prepare your quotation.