Fire rated doors

Fire Rated Acoustic Doors for Hotels, Hospitals and Plant Rooms

Fire rated acoustic doors carry a fire compartment and a sound rating on one leaf. YK Door builds FD30 and FD60 timber and steel acoustic fire doors tested to EN 1634-1 for the fire duty and to ASTM E90 or ISO 10140 for the acoustic duty, with both seals in one tested specimen.

EN 1634-1STC 35–50one tested buildcombined drop seal
Fire-rated acoustic door with vision panel in a studio corridor
Fire-rated acoustic door with vision panel, closer and lever handle
Fire-rated acoustic door standing open in its frame
02 / Overview

One leaf, two ratings

A fire rating and a sound rating meet in the same 3 mm (0.12 in.) gap at the head. Fire wants a seal that swells; sound wants a gap that stays compressed. We resolve both in one detail and test it as one build, so the opening carries a fire compartment and an acoustic target on a single doorset.

Product views

Fire-rated acoustic doors from every angle

Six views of one fire-rated acoustic door set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.

1 / 6
Fire-rated acoustic door, front view
Fire-rated acoustic door seen from the hinge side
Fire-rated acoustic door shown open
Close-up of the fire-rated acoustic door lever handle and lock
Cut-away section of a fire-rated acoustic door showing the leaf core and frame
Fire-rated acoustic door installed in a hotel corridor
Models and sizes

Models, configurations and sizes

Each model ties to its own test or certification route, so the door you order is the door that was tested.

ModelConfigurationPerformanceStandard
YK-A45FSingle, double, unequal pairFire 30 or 60 min with STC 35–50 / Rw 35–50 dBEN 1634-1, ASTM E90, ISO 10140-2

Sizes and build

Single leaf
Built to the project opening
Double leaf
Built per door set
Largest covered size
Single 1200 × 2400 mm
Leaf thickness
44 mm (FD30), 54 mm (FD60)
Materials and finish
Steel or timber faces, fire core with constrained damping layer; powder coat, veneer or laminate
Other sizes

Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.

Single swingDouble swingPersonnel opening, single leafWide opening, double leaf or bi-parting

Related products

Compare in the product finder

03 / What it covers

Tested performance and evidence routes

DutyTest or rating routeWhat we issue
Fire resistanceTested to EN 1634-1, classified to EN 13501-2; UL 10B/10C where specifiedFD30 and FD60 timber and steel builds on their own reports; FD90 on YK-S90 at EI2 90
Sound insulation, USTested to ASTM E90, rated to ASTM E413STC 35 to 50 on the tested build
Sound insulation, EU and internationalTested to ISO 10140-2, rated to ISO 717-1Rw 35 to 50 on the tested build
GlazingFire-rated acoustic laminated glass in the tested sizeBead and edge detail inside the tested specimen
Quality systemISO 9001:2015Tested build and shipped build kept the same

Both duties are tested on the same specimen where the laboratory can run both. Our acoustic steel doors and steel fire doors cover openings that carry one duty only.

Evidence

Certificates and test reports for fire rated acoustic doors

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

Acoustic test report for YK Door steel acoustic doors, STC 48 and Rw 47
STC 48 and Rw 47 · acoustic performance, steel acoustic doorsets
04 / Overview

Where the fire seal and the sound seal meet

A fire door relies on the intumescent strip expanding at about 200 °C (392 °F) to close the gap against smoke and hot gas. An acoustic door relies on the same gap staying compressed by a gasket at room temperature. We place the intumescent strip in the rebate and the acoustic gasket on the stop, in different planes, so each seal does its own job.

The threshold carries a combined drop seal and intumescent detail. NFPA 80 allows a 19 mm (3/4 in.) undercut; the drop seal closes it for sound and the intumescent element closes it for fire, and both sit in the tested specimen.

Sound also travels through the frame joint. We detail a backer rod and sealant at the frame-to-wall line and confirm the wall density before the frame drawing is released.

05 / Option

How the leaf and frame are built

Option

Timber leaf

Choices
FD30 at 44 mm (1¾ in.), FD60 at 54 mm (2⅛ in.), with a constrained damping layer or second skin inside the tested thickness
06 / Overview

Laboratory rating and field rating

Sound reads 5 to 10 dB lower on site once flanking paths, the frame joint and the ceiling plenum are in. We state the site acceptance value as a field rating, and we put the fire inspection on the same handover sheet, so one visit closes both duties.

07 / Building

Where our fire-rated acoustic doors go

Building

Hotels

Typical openings
Guest-room corridors where the compartment line runs along a corridor that also carries speech
FAQ

Fire-rated acoustic doors: questions buyers ask

Yes, when the same specimen is tested for both duties. The fire core, the intumescent strip and the damping layer go into one build, and the laboratory runs the fire test and the sound test on that build.

09 / Item

Specifications at a glance

ItemSpecification
Fire ratingFD30, FD60 tested to EN 1634-1; 45 or 60 min to UL 10B/10C where specified
Acoustic ratingSTC 35 to 50 / Rw 35 to 50 on the tested build
Leaf thickness44 mm (1¾ in.) FD30; 54 mm (2⅛ in.) FD60
Leaf constructionFire core with constrained damping layer; steel or timber faces
FrameSteel or hardwood with double seal landing
SealsIntumescent strip in the rebate; acoustic gasket on the stop; combined drop seal
GlazingFire-rated acoustic laminated glass in the tested size
HardwareCloser sized to leaf mass; three hinges, four on wide leaves
Maximum leaf1200 × 2400 mm (47 × 94 in.), confirmed per project
TraceabilityOne ID per door, matched to the door schedule

Evidence cards

YK-A45F

Fire-rated acoustic door

Evidence
Tested to EN 1634-1 and ASTM E90 on one build
Number
WF 442118/A
Result
EI2 60 (integrity 63 min, insulation 61 min) and STC 45
Size range
Specimen 1000×2100 mm single leaf
Construction
Steel leaf; fire core with acoustic layer; double seals; automatic door bottom; steel frame

Numbers are given as issued. See the full certificate register.

10 / Term

Terms we keep apart

01Fire resistance

How long the whole doorset holds back fire, tested to EN 1634-1 or UL 10B/10C

02STC and Rw

Single-number sound ratings from ASTM E413 and ISO 717-1, measured in the laboratory

03Field rating

The sound value measured on site with flanking paths and the frame joint in place

04Tested specimen

The leaf, frame, seals, glazing and hardware that the reports cover together

A fire-rated door and an acoustic door on separate reports describe two different products. We quote combined openings on one tested build, so the submittal shows one door for one opening.

11 / Step by step

How to specify it

Sample clauses for architects and acoustic consultants:

1

Fire rating

Doorsets shall carry the fire rating on the schedule, tested to EN 1634-1 or UL 10B/10C as the complete assembly supplied.

2

Acoustic rating

Doorsets shall achieve the STC or Rw stated, tested to ASTM E90 or ISO 10140-2 on the same specimen as the fire test where available.

3

Field value

Where a field value is required, it shall be stated separately and measured after the wall and ceiling are complete.

4

Seals

Intumescent and acoustic seals shall be part of the tested specimen; the threshold shall carry a combined drop seal.

5

Glazing

Vision panels shall be fire-rated acoustic laminated glass within the tested size.

6

Hardware

Closers shall be sized to the leaf mass, with latch engagement checked after adjustment.

12 / Weak point

Where it gives way first, and how we prevent it

01

Perimeter lift at the hinge jamb

What happens
A 2 mm (0.08 in.) lift on a 2.1 m (6.9 ft) leaf costs 4 to 6 dB above 1 kHz and opens a smoke path
How we handle it
Drop seals set on site with a feeler gauge to the finished floor
02

Substituted closer

What happens
A light closer stalls against the gasket and leaves the leaf 3 mm (0.12 in.) off the stop
How we handle it
Closer sized to the leaf mass, latch engagement recorded at handover
03

Painted intumescent strip

What happens
Paint stops the strip expanding while the acoustic reading stays normal
How we handle it
Seal line marked on the frame; decoration guidance starts at the seal
04

Unsealed frame joint

What happens
Dry-packed frames leak sound along the perimeter
How we handle it
Backer rod and sealant joint detailed at the frame-to-wall line
13 / Stage

Installation and acceptance

Stage

Delivery

What is checked
Door ID matches the schedule; seals, gaskets and drop seal present and undamaged
14 / Key points

Evidence we issue

  • Fire duty tested to EN 1634-1, with FD90 on YK-S90 at EI2 90 and the timber FD30 and FD60 builds on their own reports.
  • Acoustic duty tested to ASTM E90 or ISO 10140-2, with YK-A45 as the acoustic reference for the steel build.
  • Fire-rated glazing in the tested size, with the bead and edge detail inside the tested specimen.
  • ISO 9001:2015 quality system keeping the tested build and the shipped build the same.
  • Every rating issued for a named assembly; a change of leaf size, glazing or hardware is assessed before release.
Request a quote

Send your door schedule

Send the compartment rating, the acoustic target, the wall and ceiling build-up and the leaf sizes, and an engineer will return the tested build, the two evidence routes and a written lead time. Fire-rated acoustic doors are part of our fire-rated door range, alongside wind-load rated fire doors for external openings. Read the EN 16034 and EN 1634-1 guide for the classification route.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

Use the door schedule checklist

Your files stay with our engineering team and are used only to prepare your quotation.

Scroll to Top