Fire rated doors

Wind Load Fire Doors for External and Semi-Exposed Openings

Wind load fire doors hold a fire compartment on an external opening, where the leaf also takes wind pressure and rain. YK Door builds FD30 and FD60 steel and timber doors tested to EN 1634-1 for the fire duty and engineered to the project design wind pressure, with the frame and anchors sized for both.

EN 1634-1design wind pressureanchor reactions issueddrained sill
Pair of wind-load fire doors installed on an exterior wall
Lever handle and lock on a wind-load fire door
Wind-load fire double door with one leaf open
02 / Overview

A fire door on an external wall

An internal fire door is judged on one face and one set of gaps. An external one is pushed and pulled by wind, rained on, and expected to keep the same gap after years of pressure cycles. We size the frame and anchors to the design wind pressure, so the gap the fire test measured is the gap the door keeps.

Product views

Wind-load fire doors from every angle

Six views of one wind-load fire door set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.

1 / 6
Wind-load fire double door, front view
Wind-load fire double door seen from the hinge side
Wind-load fire double door shown open
Close-up of the wind-load fire double door lever handle and lock
Cut-away section of a wind-load fire double door showing the leaf core and frame
Wind-load fire double door installed on an exterior wall
Models and sizes

Models, configurations and sizes

Each model ties to its own test or certification route, so the door you order is the door that was tested.

ModelConfigurationPerformanceStandard
YK-S90Single, double, unequal pair (wind-load build)Fire 30 or 60 min; wind pressure calculated per projectTested to ASTM E330 at 3.5 kPa (73 psf)

Sizes and build

Single leaf
Designed to the wind load and opening
Double leaf
Designed on set width, pressure and anchorage
Largest covered size
Single 1200 × 2400 mm on the fire platform; larger openings designed per project
Leaf thickness
Set by the fire core and stiffening
Materials and finish
1.5–2.0 mm steel faces, mineral core, 2.0–3.0 mm welded frame, corrosion-resistant coating
Other sizes

Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.

Single swingDouble swingPersonnel opening, single leafWide opening, double leaf or bi-parting

Related products

Compare in the product finder

03 / What it covers

Tested performance and engineering routes

DutyTest or design routeWhat we issue
Fire resistanceTested to EN 1634-1, classified to EN 13501-2; UL 10B/10C where specifiedFD30 and FD60 builds on their own reports; FD90 on YK-S90 at EI2 90
Wind loadDesign pressure to EN 1991-1-4, or ASTM E330 where a US specification names itCalculation, deflection check and anchor reactions with the drawing set
DeflectionLimit stated by the project, commonly span/200Deflection check per opening
WeatherDrained sill, weep path and stainless threshold panSill detail on the shop drawing
FinishCoating system to the exposure categoryDry-film readings issued with the batch

The fire report and the wind calculation travel as two documents, and the submittal names which one covers which claim. For internal compartment doors, see our steel fire doors.

Evidence

Certificates and test reports for wind load fire doors

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

ASTM E330 wind load test report for YK Door wind load fire doors
ASTM E330 · wind load resistance, fire doorsets
04 / Overview

The wall decides the wind rating

Wind pressure acts on the leaf area and travels through the hinges, the frame and the anchors into the wall. A 1 kPa design pressure on a 1.2 × 2.4 m (47 × 94 in.) opening puts about 2.9 kN on the leaf, and that load reaches the structure through the anchors.

We ask for the wall build-up, the concrete or block strength and the fixing detail at RFQ stage. We specify chemical anchors into grouted cores or a continuous steel sub-frame at the hinge side, and we issue the anchor reactions so the wall engineer can check the embedment in the same drawing cycle.

Rain is the third duty. The threshold drains, the sill sheds water away from the frame, and the raised sill is drawn as part of the fire detail because it sets the undercut and the drop seal.

05 / Option

How the leaf and frame are built

Option

Leaf

Choices
1.5 to 2.0 mm (16 to 14 ga) steel skins over a mineral core, inside the tested fire thickness
06 / Overview

Working with the facade engineer

The design pressure is the same number the facade engineer uses for the cladding. We take it from the project, size the frame, anchors and hinge reinforcement to it, and issue the calculation and anchor reactions with the drawings, so the door and the wall are checked against one load.

07 / Building

Where our wind-load fire doors go

Building

Stair cores and roof access

Typical openings
External stair cores and roof-access doors where the compartment line meets the envelope
FAQ

Wind-load fire doors: questions buyers ask

It comes from the local code, the building height and the exposure at that facade, and it is the same number the facade engineer uses for the cladding. Send the pressure and the opening size, and we size the frame, anchors and hinge reinforcement to it.

09 / Item

Specifications at a glance

ItemSpecification
Fire ratingFD30, FD60 tested to EN 1634-1; 45 or 60 min to UL 10B/10C where specified
Design wind pressureProject-specific, from the local code
Deflection limitSpan/200 or as stated by the project
Leaf1.5 to 2.0 mm (16 to 14 ga) steel skins over a mineral core
Frame2.0 to 3.0 mm (14 to 11 ga) welded steel, continuous hinge reinforcement
Anchors400 to 600 mm (16 to 24 in.) centers, or a continuous steel sub-frame
SealsWeather gasket outside; intumescent strip in the rebate
ThresholdDrained sill with stainless pan and weep path
FinishCoating system to the exposure category, dry-film readings issued
TraceabilityOne ID per door, matched to the door schedule

Evidence cards

YK-S90-W

ASTM E330 tested wind load fire door

Evidence
Tested to ASTM E330; fire rating from the UL 10C listing
Number
CABR-2025-WL-0154; UL file E1753
Result
3.5 kPa (73 psf) design pressure, no permanent deformation
Size range
Single leaf to 1200×2400 mm
Construction
Steel leaf; reinforced frame; multi-point lock

Numbers are given as issued. See the full certificate register.

10 / Term

Terms we keep apart

01Fire resistance

How long the whole doorset holds back fire, tested to EN 1634-1 or UL 10B/10C

02Design wind pressure

The positive and negative pressure the opening must carry, from the local code

03Deflection limit

How far the leaf and frame may bow under that pressure, commonly span/200

04Anchor reaction

The load each fixing passes into the wall, issued for the wall engineer

A fire report describes fire performance and a wind calculation describes the structural duty. We issue both, per opening, and state which document supports which line of the schedule.

11 / Step by step

How to specify it

Sample clauses for architects and facade engineers:

1

Fire rating

Doorsets shall carry the fire rating on the schedule, tested to EN 1634-1 or UL 10B/10C as the complete assembly supplied.

2

Wind load

Doorsets shall resist the design wind pressure stated for each opening, with the calculation issued with the shop drawings.

3

Deflection

Leaf and frame deflection shall not exceed the stated limit, span/200 unless noted.

4

Anchorage

Anchor type, spacing and reactions shall be issued per opening for review by the wall engineer.

5

Threshold

The sill shall drain through a weep path, with a stainless threshold pan.

6

Finish

The coating system shall suit the exposure category, with dry-film readings issued per batch.

12 / Weak point

Where it gives way first, and how we prevent it

01

Hinge side

What happens
Gusts reverse the load on the same hinge line and loosen light fixings
How we handle it
Through-bolted or welded hinge plates above about 0.6 kPa
02

Threshold pocket

What happens
Water held in the frame pocket corrodes it from the inside
How we handle it
Drained sill, weep path and stainless pan, checked on the shop drawing
03

Coastal finish

What happens
A thin powder coat chalks and fades on an exposed coastal facade
How we handle it
Coating system to the exposure category, dry-film readings with the batch
04

Frame anchorage

What happens
Few anchors in ungrouted block let the frame move and open the head gap
How we handle it
Chemical anchors into grouted cores or a steel sub-frame, with reactions issued
13 / Stage

Installation and acceptance

Stage

Delivery

What is checked
Door ID matches the schedule; finish undamaged; anchors and sub-frame parts complete
14 / Key points

Evidence we issue

  • Fire duty tested to EN 1634-1, with FD90 on YK-S90 at EI2 90 and the FD30 and FD60 builds on their own reports.
  • Wind duty engineered to the project design pressure, with the calculation, deflection check and anchor reactions issued with the drawing set.
  • Frame gauge, anchor spacing and hinge reinforcement stated per opening.
  • ISO 9001:2015 quality system keeping the calculated build and the shipped build the same.
  • Every performance issued for a named assembly; a change of leaf size or anchor pattern is assessed before release.
Request a quote

Send your door schedule

Send the fire rating, the design wind pressure, the wall section and the sill detail, and an engineer will return the tested build, the anchor pattern, the deflection check and a written lead time. Wind-load rated fire doors are part of our fire-rated door range, alongside fire-rated acoustic doors for openings with a sound target. Read the EN 16034 and EN 1634-1 guide for the classification route.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

Use the door schedule checklist

Your files stay with our engineering team and are used only to prepare your quotation.