Series · Data center doors

Data Center Doors from Rack to Building, Made in China

YK Door builds data center doors at four levels, from perforated rack doors and hot and cold aisle doors to fire-acoustic, flood and security doors for the building, for cloud, colocation and AI compute facilities and the OEMs that equip them.

Data center steel door set with frame
Rackaislebuildingequipment level
01Rack
02aisle
03building
04equipment level
05CNC punched and laser cut
06batch production for OEMs
02 / Level

Four levels, four kinds of buyer

01

Rack

Products
Perforated rack doors, electronic-lock rack doors, front and rear doors
Main buyers
Rack makers, server OEMs
02

Aisle

Products
Hot and cold aisle doors, cage doors, aisle end doors
Main buyers
Data center integrators, operators
03

Building

Products
Data hall fire doors, acoustic doors, flood doors, forced-entry doors
Main buyers
Main contractors, door contractors, owners
04

Equipment

Products
Liquid-cooled rear door heat exchangers (RDHx), with thermal partners
Main buyers
Thermal management vendors, integrators
Product views

Data center doors from every angle

Six views of one data center door set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.

1 / 6
Data center steel door set with frame
Data center double door seen from the hinge side
Data center double door shown open
Close-up of the data center double door panic bars
Cut-away section of a data center double door showing the leaf core and frame
Data center double door installed in a server hall
Models and sizes

Models, configurations and sizes

Each type is engineered to the opening and verified on the route your project names.

ModelConfigurationPerformanceStandard
Project-engineeredRack, aisle and building doorsFire and acoustic to the specificationUL 10B/10C, EN 1634-1
Sizes

Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.

Cabinet and enclosure doorSingle swingDouble swingSlidingCabinet, rack and modulePersonnel opening, single leafWide opening, double leaf or bi-parting

Related products

Compare in the product finder

03 / Overview

Rack doors are measured in millimeters

A rack door looks simple, but a hole pattern 1 mm off can stop it fitting, and an open area 2% short changes airflow and heat rejection. We hold hole position with CNC punching and laser cutting, hold batch consistency with standard tooling and first-article approval, and design the lock, hinges, grounding and packaging for each customer. That is why rack and server OEMs use us as a batch supplier, with change control on every revision. For AI compute and energy storage cabinets that also need fire separation, see cabinet fire doors.

Data center door open onto a server hall
04 / Level

What we specify for each level

01

Rack door

What we confirm
Interface dimensions, hole pattern and open area, airflow, grounding, locks, coating, batch size and takt time
02

Aisle door

What we confirm
Module interface, airflow management, access control, fast installation
03

Building door

What we confirm
Fire rating, STC or Rw, flood depth and duration, forced-entry level
04

Rear door heat exchanger

What we confirm
Heat load, air and water pressure drop, water quality, hose connections, condensation control, rack fit, maintenance space
Evidence

Certificates and test reports for data center doors

The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

ift FB4 ballistic resistance test report for YK Door bullet resistant doors to EN 1522 and EN 1523
ift · FB4 ballistic resistance, EN 1522 and EN 1523
ift RC3 burglar resistance test report for YK Door security doors to EN 1627
ift · RC3 burglar resistance, EN 1627
IEC 60529 IP54 ingress protection test report for YK Door cabinet fire doors
IEC 60529 · IP54 ingress protection, cabinet doorsets
05 / Key points

Building-level doors for the data hall

Cutaway of a data center door showing mineral wool core and steel stiffeners
Fire doors

UL listed and CE marked steel fire doors for data halls and plant rooms. See fire-rated doors.

Fire-acoustic doors

For generator and chiller rooms next to occupied space. See acoustic doors.

Flood doors

Tested to ASTM E331 at 1,200 Pa for 30 minutes with no leakage. See flood doors.

Forced-entry doors

Classified RC3 under EN 1627 for critical rooms. See security doors.

06 / Key points

Who we supply

  • Cloud and internet data centers
  • Telecom operators
  • Financial data centers
  • AI and intelligent computing centers
  • Rack and server OEMs
  • Modular data center builders
FAQ

Questions buyers ask first

Talk to an engineer

Want to see a certificate or talk through a schedule? Message our engineers directly.

WhatsApp +86 189 0371 1702[email protected]Contact form

Yes. We build front and rear rack doors to customer drawings with CNC punching and laser cutting, first-article approval and change control for batch supply.

08 / Level

The data center range at a glance

01

Rack

Products
Perforated, electronic-lock, front and rear doors
What we hold to
Hole position, open area, grounding, coating, batch consistency
02

Aisle

Products
Hot and cold aisle doors, cage doors, aisle end doors
What we hold to
Airflow management, module interface, access control
03

Building

Products
Fire, acoustic, flood and forced-entry doors
What we hold to
Combined performance and acceptance
04

Equipment

Products
Liquid-cooled rear door heat exchangers
What we hold to
Heat load, pressure drop, condensation control

For cabinet doors with fire separation, see AI compute cabinet doors.

Models and evidence

ModelEvidenceNumberResultSize
YK-DCTested to IEC 60529SGS-CN-2025-IP-0731IP54; perforation 63 to 78%Single door to 800×2200 mm; pair to 1600×2200 mm
YK-C40Classified to EN 12207SRIBS-2024-AC-0186Class 4 at +600 PaSingle leaf to 1200×2400 mm
YK-S90UL 10B and UL 10C listed; cUL listed; WH listedUL file E1753 (FD-10B-01, FD-10C-01); WHI20-28643190 min single leaf, 60 min pairSingle leaf to 1200×2400 mm; pair to 2400×2400 mm

Numbers are given as issued. See the full certificate register.

09 / If you are

Choosing by buyer

01A rack or server OEM

Rack doors to your drawings, in batches

02A data center integrator

Aisle doors and cage doors with fast installation

03A main or door contractor

Building-level fire, acoustic, flood and security doors

04A thermal management vendor

Rear door heat exchanger shells with partners

05An owner or operator

The whole door package under one supplier

10 / Step by step

How to specify data center doors

01

Rack doors

Built to customer drawings and IEC or ANSI rack accessory requirements, with hole pattern, open area and grounding stated.

02

Aisle doors

Module interface, airflow and access control as shown.

03

Building doors

To the project fire, acoustic and watertight standards for each opening.

04

Grounding and EMC

To project requirements.

05

Heat exchangers

Heat load, pressure drop, water quality and maintenance interface defined.

06

Batch control

First-article approval and change control for rack and aisle doors.

11 / Step

From drawing to data hall

StepRack and aisle doorsBuilding doors
StartOEM drawing reviewDoor schedule and project specification
ApprovalFirst articleSubmittal against fire and acoustic specifications
ProductionTooling-based batchesDoor by door, one ID each
DeliveryPacked to your takt timePacked and labeled by opening
HandoverBatch recordsInstallation and acceptance records
Request a quote

Send us your drawings

Send rack drawings or the building door schedule, and an engineer will reply with a configuration and batch plan. As a China specialty door manufacturer, we cover every door level in the data center.

1An engineer reviews each opening against its wall, standard and market.
2You receive a priced configuration per opening, or the questions that stand in the way.
3On approval, we send the English submittal with drawings, data sheets and an evidence index.

OEM and ODM partnership

Your files stay with our engineering team and are used only to prepare your quotation.