Browse all articlesYK Door makes front and rear cabinet doors for AI server racks: perforated for airflow, locking, grounded and finished to your rack drawings, in OEM batches. They come from the same Henan factory that builds our fire doors, with CNC punching, laser cutting and one ID per door.



A rack door looks simple. In practice, a hole pattern 1 mm off can stop it fitting, and an open area 2% short raises air resistance and cuts heat removal. With AI racks drawing more power per cabinet, airflow through the door matters more than ever. We hold hole positions with CNC punching and laser cutting, and hold batches steady with standard tooling and first-article approval.
Six views of one ai compute cabinet door set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.






Each type is engineered to the opening and verified on the route your project names.
| Model | Configuration | Performance | Standard |
|---|---|---|---|
| AI cabinet door, ventilated | Single or split pair, removable | 63–78% open area | IP54 / NEMA 3R outdoor cabinet interface |
| AI cabinet door, barrier | Single or split pair, removable | Mineral board barrier core | IP54 / NEMA 3R outdoor cabinet interface |
| AI cabinet door, rear heat exchanger | Single or split pair, removable | Built around the rear door heat exchanger | OEM interface |
Sizes and build
Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.
Related products
For racks moving to liquid cooling, rear door heat exchangers are thermal equipment with water circuits, pressure drop and condensation control. We deliver them with specialist thermal partners against your heat load, flow and maintenance needs, and supply the door structure and fit.
Cabinet doors are the first layer. The same factory supplies the aisle doors, the fire-acoustic data hall doors, the flood doors at plant level and the security doors on critical rooms, so one supplier covers the data center from rack to building envelope. See data center doors and doors for data centers.

Our cabinet doors are the rack layer of work we already do for data centers. The building doors on the project below and the YK-DC cabinet door come off the same Henan lines, under the same one-ID-per-door records.
Open area decides how much air the servers get through the door. Enter the hole size and pitch from your drawing to see where it lands against the YK-DC range.
Formula: 60° staggered = 90.69 × (d/p)²; square grid = 78.54 × (d/p)². We confirm the final figure on the first article.
| Item | Ventilated door | Barrier door | Rear heat exchanger door |
|---|---|---|---|
| Leaf size | 600–800 × 2000–2200 mm; single to 800 × 2200 mm, split pair to 1600 × 2200 mm; other sizes to the OEM interface | ||
| Face | Perforated steel, 63–78% open area | Solid face, mineral board barrier core | Frame built around the heat exchanger coil |
| Thickness | Set by the panel | 50–75 mm | Set by the heat exchanger |
| Ingress | IP54 / NEMA 3R outdoor cabinet interface | IP54 / NEMA 3R outdoor cabinet interface | OEM interface |
| Material | Cold-rolled steel or stainless, CNC punched and laser cut on fixed tooling | ||
| Hinges | Removable, tested to 50,000 cycles | ||
| Locks | Mechanical or electronic, fitted and checked before shipping | ||
| Grounding | Points and bonding to your drawing; continuity checked on every door | ||
| Finish | Powder coat in your color; adhesion and film thickness checked per batch | ||
| Evidence | Tested to IEC 60529, IP54 (SGS-CN-2025-IP-0731) | ||
Rear heat exchanger doors are delivered with specialist thermal partners; we build the door structure and fit.
The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

Yes. Send your drawings and a sample if you have one. We check fit and open area on a first article before the batch runs.
Yes. Locks, hinges and grounding are fitted to your drawing so doors arrive ready for assembly.
Yes, with specialist thermal partners. We build the door structure and coordinate the thermal side to your requirements.
Yes. Open area is set by the hole pattern on your drawing and held by CNC punching and fixed tooling, checked on the first article.
Yes. Grounding points and bonding are fitted to your drawing before shipping.
Powder coat as standard, in your color, with adhesion and film thickness controlled per batch.
Numbers are given as issued. See the full certificate register.
Interface dimensions and hole pattern per the rack drawing.
Open area as stated.
Bonding points as shown.
Coating type and color, adhesion and film thickness checks.
First-article approval before volume; change control throughout.
Tick what you already have. The more boxes ticked, the faster an engineer can price the first article and the batch. Missing items are fine: we list them back as questions.
Files go with the form below (PDF, DWG, Excel or images). You can also reach us through the contact page.
Send the interface dimensions, hole pattern, open area, grounding, locks, coating and batch plan, and an engineer will reply with a first-article plan. These doors are part of our cabinet fire door range, alongside energy storage cabinet doors. Read about YK Door as a specialty door manufacturer in China.
Your files stay with our engineering team and are used only to prepare your quotation.