Single leaf 90 minutes, double leaf 60 minutes, also CE marked and Certifire certified for export projects.
See fire-rated doorsAll products, with filters
X-ray, CT, MRI RF, airtight theater and fire doors on one submittal set, one ID per door.
See healthcare doors
How to read what a certificate, listing or test report actually proves.
Read the guide
Engineering guides on sourcing, test evidence and every specialty door type, written by YK engineers.
Browse all articles
YK Door builds doors for battery energy storage cabinets and containers that keep fire separation and airtightness, open outward for escape, and let rescuers in from outside. They are made on our fire door lines in Henan, China, with A1-classified cores, ISO 3834-2 certified welding and one ID per door.
Thermal runaway links ignition, gas release, pressure rise and spread from module to module. A BESS door touches all four. It must hold fire separation between compartments, keep gas where the ventilation and relief design expects it, avoid becoming a projectile, and still let people out and rescuers in. We design the door as a part of the system's safety design, together with the system integrator.
Six views of one energy storage cabinet door set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.






Each type is engineered to the opening and verified on the route your project names.
| Model | Configuration | Performance | Standard |
|---|---|---|---|
| Storage cabinet door, insulated | Single, double, removable | Insulated solid core | IP54 / NEMA 3R cabinet interface |
| Storage cabinet door, fire damper | Single, double, removable | Fire damper integrated | IP54 / NEMA 3R cabinet interface |
| Storage cabinet door, pressure relief | Single, double, removable | Relief element, typically 5 kPa | IP54 / NEMA 3R cabinet interface |
Sizes and build
Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.
Related products
| Door | Key requirements | How we build it |
|---|---|---|
| Battery compartment door | Fire division, airtightness, quick escape, external rescue | Combined fire-rated and airtight construction, outward opening for escape |
| Container door | Weather resistance, sealing, reliable locking | Heavy-duty hardware, weather-resistant coating |
| Access and equipment door | Frequent opening, secure locking, corrosion resistance | Heavy-duty hinges and multi-point locks |
| Fire separation door | Fire integrity, self-closing, smoke tightness | Taken from our approved fire door configurations |
| Pressure relief interface | Relieves as designed, nothing breaks loose | Coordinated with the venting designer, opening pressure verified on its own. See explosion venting doors. |
Each fire rating belongs to the configuration that earned it. We select the fire separation door from our approved configurations and never carry a rating across to a different build. Where a cabinet door needs a new configuration, it goes through technical review first. See our certifications.
Seals and drip details for outdoor cabinets and containers
Weather-resistant coatings: powder coat, fluorocarbon, or galvanized and painted
Heavy-duty hinges, multi-point locks
Hardware and seals protected for shipping. See container fire doors.
The same team builds doors for the factories that make the cells: battery dry room doors with inflatable seals and airlocks, and fire separation doors for battery warehouses.
For storage system makers, we supply doors to your cabinet drawing in repeat batches: CNC punched and laser cut for exact hole positions, first-article approval, a frozen bill of materials, change control, and packing and labeling for your assembly line. Interface drawings define what belongs to the door and what belongs to the cabinet.
These photos come from our own shop floor in Henan. They show a batch of double-leaf doors for battery energy storage containers being fitted, checked and shipped on the container itself. The client's name stays confidential; the build steps below are the ones every OEM batch goes through.


WhatsApp and WeChat: +86 189 0371 1702. Batch inspection records and door ID samples go out with every OEM quotation.
A storage project usually has three kinds of opening. This sheet puts them side by side with the ranges we build to; the integrator's drawing sets the exact door.
| Item | Container door | Cabinet door | Battery room fire door |
|---|---|---|---|
| Where it goes | Battery container wall, personnel and service access | Outdoor battery, PCS or liquid-cooled cabinet front | Indoor battery room or BESS building |
| Format | Single or double leaf, outward opening | Single or double, removable leaf | Single, double or unequal pair |
| Leaf size | 600–1200 × 1800–2200 mm per leaf; sets built to the container opening | 600–1200 × 1800–2200 mm; other sizes to the OEM interface | Single 600 × 1800 to 1200 × 2400 mm; pair to 2400 × 2400 mm |
| Leaf thickness | 50–75 mm | 50–75 mm | 45–55 mm |
| Skins | 1.0–2.0 mm galvanized or stainless steel | 1.0–2.0 mm galvanized or stainless steel | 1.5 mm galvanized steel, both faces |
| Core | Insulated mineral board core | Insulated solid core, or fire damper integrated | Rock wool, 100–120 kg/m³, classified A1 under EN 13501-1 |
| Seals | Intumescent and silicone seals | Intumescent and silicone seals | Intumescent seals; cold smoke seals on the smoke control build |
| Ingress | IP54 sealing detail | IP54, tested to IEC 60529 (SGS-CN-2025-IP-0731); NEMA 3R interface | Indoor service; smoke control build UL 1784 listed |
| Pressure relief | Relief element in the leaf or wall, typically 5 kPa, set with the venting designer | Pressure relief door option, typically 5 kPa | Vent doors tested to EN 14797 at 2, 5 or 10 kPa where the room needs them |
| Escape and access | Panic exit hardware inside, external access for responders | Service access with multi-point locks; door status signal on request | Panic or lever hardware from the listed options |
| Fire evidence | Built on our fire door lines; configuration reviewed per project | Fire damper option; configuration reviewed per project | UL 10B and UL 10C listed, 90 min single, 60 min pair (UL file E1753) |
| Hinges and locks | Heavy-duty hinges, multi-point locks | Removable hinges tested to 50,000 cycles | Listed hardware (Dorma TS83, Häfele) |
| Finish | Powder coat, fluorocarbon, or galvanized and painted for coastal sites | Powder coat to your RAL color | Powder coat |
| Batch control | First-article approval, frozen bill of materials, change review, one ID per door linked to drawings, material batches and inspection records | ||
Fire ratings belong to the listed configuration that earned them. Container and cabinet doors are reviewed against those configurations before production. See the certificate register.
The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

Yes. Battery compartment doors open outward for escape, with access for rescuers from outside.
Yes. We coordinate the door and relief interface with your venting designer, and the opening pressure of the relief device is verified on its own.
Yes. We supply OEM batches to your drawings, with first-article approval and the same bill of materials in every batch.
Neither is the universal answer. It depends on use, project requirements and the risk assessment, and we agree it in the control state table at concept stage.
Yes. Door status can be fed to the system's controls where the integrator needs it, agreed in the interface drawing.
Yes. Fire separation doors come from our steel fire door configurations, UL 10B and UL 10C listed and tested to EN 1634-1, up to 90 minutes.
Projects in North America usually reference NFPA 855 and UL 9540A, and projects elsewhere IEC 62933-5-2. We supply the door data, drawings and evidence for the integrator's file.
Leaves 600 to 1200 mm wide and 1800 to 2200 mm high, 50 to 75 mm thick. Other sizes are built to the OEM interface.
The fire, smoke and relief values on a BESS door come from these configurations. Each cabinet door is built to the integrator's drawing and reviewed against them before production. Numbers are given as issued. See the full certificate register.
Doors shall provide the separation required by the system's safety design, from an approved configuration.
Seals as needed to keep gas within the ventilation and relief design.
Outward opening for escape, with external rescue access.
Interface with the pressure relief device coordinated with the venting designer.
First-article approval and frozen bill of materials for OEM supply.
| Code | What it asks of the door | What we supply |
|---|---|---|
| NFPA 855 | Fire separation, explosion control and responder access around energy storage rooms, cabinets and containers | Fire separation doors from our listed configurations, outward opening, external rescue access |
| UL 9540 and UL 9540A | System listing, and the thermal runaway test that sets separation and venting needs | Door data sheets and interface drawings for the integrator's test file |
| IEC 62933-5-2 | Safety requirements for electrochemical energy storage systems | Door data, material classes and seal details for the system's safety file |
| NFPA 68 | Deflagration venting: vent area and activation pressure | Relief interface coordinated with the vent design; vent doors tested to EN 14797 at 2, 5 or 10 kPa |
| NFPA 69 | Explosion prevention by gas detection and exhaust | Door seals that keep gas inside the ventilation path |
| EN 13501-1 and EN 13501-2 | Reaction to fire and fire resistance classes in Europe | A1 core; EI2 classes from our CE marked steel fire doors |
The integrator holds the system listing and the safety file. We supply the door evidence, drawings and data that go into it. See explosion venting doors and smoke control doors.
The summary below updates as you go. Send it to the quote form on this page or straight to an engineer on WhatsApp.
1. Which opening?
2. What must it do?
3. Code basis
4. Quantity
5. Leaf size (optional)
Prefer email or a call? Use the contact page. Attach cabinet or container drawings in the form below and an engineer replies with a configuration.
Send the cabinet or container drawings, fire and sealing needs, escape and rescue directions, hardware, finish and batch plan, and an engineer will reply with a configuration. These doors are part of our cabinet fire door range, next to AI compute cabinet doors. Read about YK Door as a China specialty door manufacturer.
Your files stay with our engineering team and are used only to prepare your quotation.