Single leaf 90 minutes, double leaf 60 minutes, also CE marked and Certifire certified for export projects.
See fire-rated doorsAll products, with filters
X-ray, CT, MRI RF, airtight theater and fire doors on one submittal set, one ID per door.
See healthcare doors
How to read what a certificate, listing or test report actually proves.
Read the guide
Engineering guides on sourcing, test evidence and every specialty door type, written by YK engineers.
Browse all articles
YK Door builds gastight doors for rooms that must hold their air in or keep it out: BSL-2 and BSL-3 laboratories, animal rooms, decontamination areas and lithium battery dry rooms. Inflatable seals, airlock interlocks and defined power-failure and fire-alarm behavior are designed in from the start.
Six views of one gastight doors and airlock set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.






Each type is engineered to the opening and verified on the route your project names.
| Model | Configuration | Performance | Standard |
|---|---|---|---|
| Gastight, compression seal | Single; pairs per door set; airlock interlock | Working pressure and leakage rate to the project | Pressure decay or tracer gas test |
| Gastight, inflatable seal | Single; pairs per door set; airlock interlock | Working pressure and leakage rate to the project | Pressure decay or tracer gas test |
Sizes and build
Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.
Related products
Only one door of an airlock opens at a time.
A fire alarm overrides the interlock so people can leave.
An emergency stop releases the doors.
On power failure, the doors open in the way the safety plan defines.
Every state is signaled to the building system.
Containment rooms are cleaned and decontaminated often. We choose seal materials, coatings and joints for the agents and methods your facility uses, keep surfaces flush with no ledges where residue collects, and keep penetrations sealed. Our airtight construction is tested to EN 12207 Class 4 on the YK-C40 model, and the project's own leakage figure, pressure and measurement method set the target for each door.
Battery dry rooms run at a very low dew point. Every door opening lets moist air in. We use inflatable seals, low-permeability leaves and airlock logic to keep moisture out, and size the airlock to the opening frequency of the room.
Containment doors, airlocks, pass boxes
Containment doors with interlocks
Inflatable seal doors on high-grade zones. See cleanroom doors.
Dry room doors and airlocks. See cabinet fire doors for energy storage.
Isolation and negative-pressure rooms. See hermetic airtight doors.
The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.

Yes. Fire alarm takes priority over the interlock in our control scheme, so people can leave.
The system protects the seal and signals the fault, and the door's power-failure behavior follows the safety plan for the room.
The target dew point, pressure difference, moisture requirement, how often the door opens, and the airlock logic.
Bladders are wear parts. Because they deflate before the door moves, they do not rub on the frame. We supply spares and a replacement interval.
Yes. Pass boxes have interlocked doors so only one side opens at a time.
Flush, sealed surfaces with coatings and seals chosen for your disinfection agents.
Numbers are given as issued. See the full certificate register.
Very low leakage at a stated pressure
Keeping biological agents inside, with disinfection
The moisture level a dry room must hold
Two interlocked doors that are never open together
Leakage rate, pressure, direction and measurement method as scheduled.
Inflatable seals with pressure-loss protection where scheduled.
Airlock doors interlocked, with fire alarm, emergency stop and power-failure priority.
Seals and surfaces compatible with the stated agents.
Control state table and documents suitable for validation.
Send the containment level or dew point, pressures, leakage figure and room layout, and an engineer will reply with a configuration. Gastight doors are part of our airtight and cleanroom door range. Read about YK Door as a specialty door manufacturer in China.
Your files stay with our engineering team and are used only to prepare your quotation.