Single leaf 90 minutes, double leaf 60 minutes, also CE marked and Certifire certified for export projects.
See fire-rated doorsAll products, with filters
X-ray, CT, MRI RF, airtight theater and fire doors on one submittal set, one ID per door.
See healthcare doors
How to read what a certificate, listing or test report actually proves.
Read the guide
Engineering guides on sourcing, test evidence and every specialty door type, written by YK engineers.
Browse all articles
YK Door builds storm shelter doors for tornado and hurricane shelters and safe rooms, tested to ICC 500 and FEMA P-361 as complete assemblies: leaf, frame, hardware and anchorage to the wall, in the configuration they will be installed.
A thick steel door does not protect a shelter on its own. Wind pressure and flying debris test the whole opening: the leaf, the latch points, the hinges, the frame and the anchors into the wall. A shelter door is designed and approved as a complete assembly in its installed configuration, and that is how we build it. How shelter ratings sit beside ballistic and forced-entry classes is set out in our guide to security door rating levels.
Six views of one storm shelter door set: the face, the hinge side, the open leaf, the hardware, the section and the door in service. Open any view full screen to see the detail.






Each model ties to its own test or certification route, so the door you order is the door that was tested.
| Model | Configuration | Performance | Standard |
|---|---|---|---|
| YK-SH | Single; sets per safe room design | Windborne debris impact and cyclic wind pressure | ICC 500, FEMA P-361 |
Sizes and build
Built to your opening size. Send the clear opening and wall type, and we confirm the leaf, frame and hardware with drawings.
Related products
The documents behind the claims on this page, at the model and configuration that were assessed. Copies go with the submittal for your project.


We supply installation details for the wall type and a maintenance schedule for hardware and latching, in line with FEMA guidance on shelter door installation and maintenance.
Yes. Our storm shelter doors are tested to ICC 500 and FEMA P-361 as complete assemblies, including anchorage.
Yes. Every shelter door has an inside release for leaving once the storm has passed.
Yes. We supply the leaf, frame, hardware and anchorage details as one assembly matched to the wall.
Yes. Anchorage is part of the shelter assembly. We match the anchors to the wall type on the drawing, because the wall connection carries the load.
Only if the panel is part of the assembly configuration designed for the shelter. A panel added later changes the assembly.
Regular checks of latching, hinges and anchors, following FEMA guidance on shelter door installation and maintenance. We supply a checklist.
Numbers are given as issued. See the full certificate register.
Door assemblies shall be tested to ICC 500 and FEMA P-361 for the shelter type shown.
Leaf, frame, hardware and anchorage shall be supplied as one configuration, as installed.
Anchorage shall match the wall type on the drawings.
Multiple latch points that stay engaged under reversing pressure.
Occupants shall be able to open the door from inside.
Installation details and a maintenance checklist with each door.
Build-up matches the anchorage design
Anchored to the detail, plumb and square
Hung, every latch point engages
Inside release tested
Door ID, configuration and installation record
Send the standard, shelter type, wall details and door schedule, and an engineer will reply with a configuration. Shelter doors are part of our storm shelter, safe room and detention door range, alongside detention doors. Read about YK Door as a specialty door manufacturer in China.
Your files stay with our engineering team and are used only to prepare your quotation.