
Single leaf 90 minutes, double leaf 60 minutes, also CE marked and Certifire certified for export projects.
See fire-rated doorsAll products, with filters
X-ray, CT, MRI RF, airtight theater and fire doors on one submittal set, one ID per door.
See healthcare doors
How to read what a certificate, listing or test report actually proves.
Read the guide
Engineering guides on sourcing, test evidence and every specialty door type, written by YK engineers.
Browse all articles
Engineering guides for the people who specify, buy and approve protective openings: how to source specialty doors from China, what test evidence proves, and how each door type is built and rated. Written and reviewed by YK Door engineers.
Open a topic to see its cornerstone guides, the full question series and every published article.

Buying specialty doors from China, from RFQ to site acceptance.
Open topic
What certificates, listings and test reports prove, and US code compliance.
Open topic
How fire-rated door assemblies are built and how combined ratings are proven.
Open topic
Blast, explosion, ballistic, forced-entry and shelter doors.
Open topic
X-ray, CT, linac and MRI room doors.
Open topic
Cleanroom, airtight, laboratory and acoustic doors.
Open topic
Flood, watertight, marine, offshore and tunnel doors.
Open topic
Data center, hangar, high-speed and other large industrial doors.
Open topicEach cornerstone guide covers one subject end to end and anchors a series of shorter articles.
Cornerstone guide
Cornerstone guide
Cornerstone guide
Cornerstone guide
Cornerstone guide
Cornerstone guide
Cornerstone guide
Cornerstone guide
Door supplier product liability insurance protects an importer only when it actually responds to US claims.
Read article 10 min read
A specification compliance matrix is a table that lists every clause of the door specification, states whether the offer complies.
Read article 10 min read
ISO 3834-2 welding certification shows that a manufacturer meets the comprehensive quality requirements for fusion welding: qualified procedures.
Read article 10 min read
A CNAS accredited test lab is a laboratory accredited by China’s national accreditation body to ISO/IEC 17025 for specific test methods.
Read article 10 min read
Notified body fire door certification under EN 16034 follows AVCP System 1. A notified product certification body checks the product’s type testing.
Read article 10 min read
Fire door extended application (EXAP) is a documented assessment, under the EN 15269 series.
Read article 10 min read
To read a fire door test report, start with what was tested, not the result. Check the specimen description (size, leaf, frame, hardware, glass, seals).
Read article 10 min read
To check a UL listing for a fire door, search UL Product iQ by company name, file number or model, open the product’s category page.
Read article 10 min read
In a listed vs tested door comparison, the difference is follow-up. “Tested to” means one specimen passed a named test.
Read article 10 min read
Turn X-ray room door shielding requirements into a clear specification. Check lead equivalence, frames, glazing and survey details with YK Door.
Read article 22 min readCompare security door rating levels for ballistic, forced-entry and storm threats. Match UL 752, EN 1627 and ICC 500 evidence to your door schedule.
Read article 23 min read
Compare blast-resistant, explosion-venting and containment doors. Match hazard loads, opening behavior and project evidence before requesting a quote.
Read article 22 min read
Specify combined performance door ratings for fire, acoustic, smoke and wind loads. Match seals, hardware and glazing to the evidence with YK Door.
Read article 20 min read
Explore fire-rated door assembly components, from the frame and core to hardware, glazing and seals, with practical selection guidance from YK Door.
Read article 21 min read
Understand US code compliance for imported fire doors, including UL listings, labels, NFPA 80 installation and documents for project review.
Read article 22 min read
Learn how to verify a door test report, listing and scope. Check model, size, hardware and evidence against your project schedule with YK Door.
Read article 23 min read
Follow the specialty door submittal process from approved drawings and configuration freeze to FAT, installation, SAT and handover with YK Door.
Read article 22 min read
Learn how to source specialty doors from China, compare suppliers and quotations, and coordinate drawings, quality checks and delivery with YK Door.
Read article 22 min readNo article matches that search yet. Try a shorter phrase or another topic.
Pick the situation closest to yours and read the guides in this order.
You are sourcing a specialty door package and want a factory you can rely on.
You write the door specification and need each requirement backed by the right evidence.
You need a US authority having jurisdiction to accept an imported door.
You are planning blast, ballistic or radiation-shielded rooms.
Use three checks. Confirm you are talking to the factory that makes the doors and signs the drawings. Read more in How to Source Specialty Doors from China
For each door type: the product data sheet, a general arrangement drawing, installation details for each wall type, a statement of the performance range and its limits, the hardware schedule, glazing details, finishes, an inspection and test plan, and an evidence index that maps each performance clause to its supporting document. Read more in From Door Schedule to Site Acceptance
A test report shows that one specimen passed one test in one laboratory. A certification or listing adds ongoing control: the certification body reviews the tested design, defines what may vary, audits the factory and keeps returning. Read more in Certificate, Listing or Test Report? How to Verify What a Door’s Paperwork Actually Proves
Yes. Imported fire doors follow the same product-evaluation and installation framework as domestic doors. Read more in Imported Fire Doors
The leaf (skins, core and reinforcement), the labeled frame and its anchors, hinges, positive latching hardware, a closer and, on pairs, a coordinator, the listed seals, any marked fire-rated glazing in a listed kit, and clearances held within the NFPA 80 limits. The listing decides which version of each is permitted. Read more in Anatomy of a Fire-Rated Door Assembly
Yes, when the fire evidence and the acoustic evidence describe the same configuration, including the seal set and threshold. Check that the seals and drop seal behind the acoustic result are present in the fire-tested or fire-listed build. Read more in When One Door Has to Do Two Jobs
A blast door is a door assembly designed to stay closed and in one piece when the pressure wave from an explosion strikes it, and to resist the rebound that follows. It is rated for a pressure-time load from a stated direction, given as peak reflected pressure and impulse, and proven by test to a standard such as ASTM F2927 or by engineering calculation for the complete door. Read more in Blast-Resistant, Explosion-Venting or Explosion-Proof? Choosing the Right Door for the Hazard
Forced entry doors are complete doorsets tested to resist an attacker with hand and power tools for a stated working time. In Europe they are classified under EN 1627 from RC1 to RC6. Read more in Bullet-Resistant, Forced-Entry and Storm Shelter Doors
Upload your door schedule or specification and an engineer maps each clause to a configuration and the document behind it. Learn more about YK Door, a China specialty door manufacturer.
Your files stay with our engineering team and are used only to prepare your quotation.