Single leaf 90 minutes, double leaf 60 minutes, also CE marked and Certifire certified for export projects.
See fire-rated doorsAll products, with filters
X-ray, CT, MRI RF, airtight theater and fire doors on one submittal set, one ID per door.
See healthcare doors
How to read what a certificate, listing or test report actually proves.
Read the guide
Engineering guides on sourcing, test evidence and every specialty door type, written by YK engineers.
Browse all articlesFire-rated doors earn their rating as complete assemblies: leaf, frame, core, hardware, glazing and seals tested together. These guides take that assembly apart component by component, explain why each part matters in a fire, and show which substitutions keep or break the rating. A second pillar covers doors that must do two jobs at once, such as fire plus acoustic, smoke, wind load, security or radiation shielding, and explains how combined performance is proven rather than assumed. Written for architects, door and hardware consultants and buyers who want to specify fire doors with confidence.
Fire and Smoke ProtectionEach cornerstone guide covers the whole topic end to end. The articles in its series go deeper into one question each.
Cornerstone guide
Cornerstone guideThe questions below map the article series behind each cornerstone guide. Linked titles are live; the rest are being written by our engineers.
What parts make up a fire-rated door assembly and how does each one affect the rating?
Can one door be fire-rated and acoustic (or blast, shielded, airtight), and how is that proven?

Specify combined performance door ratings for fire, acoustic, smoke and wind loads. Match seals, hardware and glazing to the evidence with YK Door.
Read article 20 min read
Explore fire-rated door assembly components, from the frame and core to hardware, glazing and seals, with practical selection guidance from YK Door.
Read article 21 min readYes, when the fire evidence and the acoustic evidence describe the same configuration, including the seal set and threshold. Check that the seals and drop seal behind the acoustic result are present in the fire-tested or fire-listed build. Read more in When One Door Has to Do Two Jobs
Yes, when the multi-point locks, reinforced frame and anchorage are part of the fire-listed configuration or permitted by it. The wind evidence and the fire evidence then cover the same hardware and frame. Read more in When One Door Has to Do Two Jobs
The 2010 ADA Standards limit interior hinged doors to 5 pounds of opening force and set fire doors at the minimum opening force allowed by the authority having jurisdiction. The closer, latch and seals are selected and adjusted together to close and latch reliably at that force. Read more in When One Door Has to Do Two Jobs
The leaf (skins, core and reinforcement), the labeled frame and its anchors, hinges, positive latching hardware, a closer and, on pairs, a coordinator, the listed seals, any marked fire-rated glazing in a listed kit, and clearances held within the NFPA 80 limits. The listing decides which version of each is permitted. Read more in Anatomy of a Fire-Rated Door Assembly
Yes, when each component is itself labeled, listed or classified, nothing in the door listing restricts the combination, and the AHJ accepts it. NFPA 80 permits that mixed sourcing, so the coordinator reads the door listing and the hardware listings side by side before production. Read more in Anatomy of a Fire-Rated Door Assembly
Mineral wool is the common choice for insulated fire doors, perlite-based cores add rigidity, and aluminum honeycomb keeps leaves light and flat where the rating allows. The core is part of the listed construction, so it is selected with the model and rating rather than swapped for an equivalent. Read more in Anatomy of a Fire-Rated Door Assembly
Upload your door schedule or specification and an engineer maps each clause to a configuration and the document behind it. Learn more about YK Door, a China specialty door manufacturer.
Your files stay with our engineering team and are used only to prepare your quotation.